Description
Emerson PACSystems RX3i IC695ALG508-AA – 8‑Channel Analog Input Module for clean, reliable voltage/current acquisition
The IC695ALG508-AA is an 8‑channel analog input module for the PACSystems RX3i platform (heritage GE Fanuc). It’s typically used when you need stable, low‑noise measurements from field transmitters—think -10…+10 V signals from drives and 4–20 mA loops from pressure, flow, or temperature transmitters. One thing I appreciate is how it fits straight into the RX3i rack and just works with existing logic—no fuss about external comms or special adapters.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- 8 analog inputs – Suited for multi-point acquisition in compact panels without adding extra racks.
- Voltage and current ranges – Typically supports -10…+10 V, 0–10 V, 0–20 mA and 4–20 mA; channels are software‑configurable.
- RX3i native backplane interface – Seamless integration with PACSystems RX3i CPUs and engineering tools.
- High‑resolution conversion – Up to 16‑bit class measurement for clean trends and better control stability.
- Noise‑aware design – In many cases you’ll see noticeably steadier readings with proper shielding and grounding.
- Status and diagnostics – You might notice faster troubleshooting thanks to per‑channel fault detection in the control software.
- RX3i form factor – Standard single‑slot module; fits IC695CHSxxx racks commonly used in OEM and plant upgrades.
Technical Specifications
| Brand / Model | Emerson PACSystems RX3i / IC695ALG508-AA |
| HS Code | 853890 (Parts suitable for industrial control panels/PLC systems) |
| Power Requirements | Backplane‑powered via RX3i power supply (3.3 V rail); no external power required for signal measurement |
| Channels / Type | 8 analog inputs; voltage and current ranges, software‑selectable per channel |
| Signal Input Types | Voltage: -10…+10 V, 0–10 V; Current: 0–20 mA, 4–20 mA (typical) |
| Resolution / Performance | Up to 16‑bit class A/D; stable readings with proper shielding and grounding practices |
| Operating Temperature | 0 to 60 °C (typical RX3i environment) |
| Communication Interface | RX3i backplane bus; no external comms ports on the module |
| Installation Method | Plugs into IC695CHSxxx RX3i rack; rack supports DIN‑rail or panel mounting |
| Approvals (typical) | CE, UL, RoHS |
Application Fields
From my experience, this module fits best where you have mixed analog sources and want to keep I/O count efficient:
- Water & wastewater – 4–20 mA flow, level, and pH transmitters into a single RX3i bay.
- OEM machinery – -10…+10 V feedback from drives, pressure loops, and force sensors on compact skids.
- Oil & gas skids – Multi‑loop pressure/temperature monitoring with clean trends for remote diagnostics.
- Power & utilities – Analog monitoring of auxiliary systems where reliability and lifecycle matter.
- Process packaging – 0–10 V web tension and 4–20 mA temperature loops in one mixed module.
Advantages & Value
- Lifecycle continuity – Stays within the RX3i ecosystem, which typically means simpler spares and fewer vendor mixes.
- Cost per point – 8 channels per slot often reduces rack footprint versus multiple small modules.
- Engineering time savings – Native configuration in RX3i tools; you might notice quicker commissioning and maintenance.
- Signal quality – 16‑bit class resolution and stable conversion give tighter control and cleaner historian data.
- Compatibility – Plays nicely with common RX3i components: IC695CHS007/012 racks, IC695PSA040 power supplies, and mainstream RX3i CPUs.
Customer feedback from a packaging OEM: “Swapping to IC695ALG508-AA cleaned up our analog noise and freed a slot. Commissioning was straightforward; per‑channel setup made range changes painless.”
Installation & Maintenance
- Panel & rack – Install in an IC695CHSxxx RX3i rack within an IP‑rated cabinet; allow ventilation around the power supply and modules.
- Wiring – Use shielded twisted pair for analog runs; ground shields at one end only to reduce hum. Separate analog from high‑voltage or motor cables.
- Loop power – For 4–20 mA loops, use clean 24 VDC loop power and observe polarity; avoid sharing commons with noisy loads.
- Configuration – Set each channel to the required range and scaling in the RX3i software; verify with a known source.
- Maintenance – Periodic verification with a calibrated handheld source (typically annually) and check terminal tightness; keep firmware and project backups current.
- Safety – De‑energize the system before inserting or removing modules; follow local electrical standards.
Quality & Certifications
- Certifications – CE, UL, RoHS (typical for RX3i I/O)
- Manufacturing quality – Built under ISO‑aligned processes for industrial environments.
- Warranty – 365‑day warranty, with replacement or repair options depending on evaluation.
Commonly Paired RX3i Components (for fast builds)
- IC695CHS007 / IC695CHS012 – 7‑slot / 12‑slot RX3i racks for compact or expanded systems.
- IC695PSA040 – 40 W RX3i power supply suitable for typical I/O mixes.
- IC695CPU310 / IC695CPU315 – Mainstream RX3i CPUs often used with mixed analog and discrete I/O.
If your application needs confirmed specs such as exact power draw per rail or channel‑to‑channel isolation details, I can check the specific IC695ALG508-AA revision data before you commit. That small step typically ensures perfect fit and avoids surprises on site.










Reviews