Description
EMERSON ROSEMOUNT 3144P (P144.R4) Temperature Transmitter — Stable, dual-sensor measurement for critical process control
The designation P144.R4 is commonly used in spares lists for the EMERSON ROSEMOUNT 3144P, Rev. 4. From my experience, this model is the go-to 2‑wire transmitter when you need reliable 4–20 mA with HART diagnostics, dual sensor inputs, and the kind of stability that keeps loops on spec for years. One thing I appreciate is the “Hot Backup” capability—if one RTD or thermocouple fails, it can seamlessly switch to the second sensor, which typically saves a shutdown and a maintenance call. It also supports advanced sensor matching for tighter accuracy in demanding processes.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery time: 1 week for in‑stock items; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- Dual sensor input with Hot Backup – Reduces process risk; automatically switches to the healthy sensor if one fails.
- 4–20 mA + HART – Easy drop‑in replacement and remote configuration via common handhelds or asset software.
- Broad sensor compatibility – Supports RTDs (2/3/4‑wire), TCs (J, K, T, E, N, R, S, B) and mV sources for maximum flexibility.
- Robust field housing – Dual‑compartment, IP66/67, NEMA 4X construction that typically stands up well to washdowns and weather.
- Advanced diagnostics – Sensor drift alerts, loop integrity checks, and configuration audit trail help maintenance teams act early.
- High accuracy and stability – Sensor matching and linearization minimize total error, especially on critical loops.
- Safety ready – Widely used in SIS applications; SIL-capable configurations are available when specified.
- Protocol choice – HART variant by default; FOUNDATION Fieldbus and PROFIBUS PA versions exist for bus architectures.
Technical Specifications
| Parameter | Details |
|---|---|
| Brand / Model | EMERSON ROSEMOUNT 3144P (often referenced as P144.R4) |
| HS Code | 9025.80 (temperature-measuring instruments and apparatus) |
| Power Requirements | Loop-powered 10.8–42.4 VDC (4–20 mA HART) |
| Operating Temperature | -40 to +85 °C for electronics (display ranges may differ) |
| Signal Input/Output Types | Inputs: RTD (2/3/4-wire), TC (J, K, T, E, N, R, S, B), mV; Output: 4–20 mA DC with HART |
| Communication Interfaces | HART (default); FOUNDATION Fieldbus / PROFIBUS PA variants available |
| Enclosure & Protection | Dual-compartment aluminum or stainless steel; IP66/67, NEMA 4X (typical) |
| Dimensions & Weight | Field-mount compact footprint; typically around 0.8–1.2 kg depending on housing |
| Installation Method | 2-inch pipe or wall mount; 1/2-14 NPT conduit entries; remote sensor wiring supported |
Application Fields
The 3144P shows up in places where a temperature loop going off-spec is costly: refinery heater outlet monitoring, reactor jackets in chemical processing, turbine bearing metal temps in power plants, and sanitary processes with frequent washdowns. You might notice it’s often paired with thermowells on high-velocity lines or with surface-mount assemblies where hot tap work isn’t practical.
Advantages & Value
- Reliability that reduces interventions – In many cases, dual-compartment sealing and diagnostics cut unplanned site trips.
- Compatibility-first – 4–20 mA with HART fits existing DCS/PLC I/O without redesign; bus variants cover modern plants.
- Lifecycle savings – Stable calibration and Hot Backup typically lower total cost of ownership over multi‑year cycles.
- Support & spares continuity – Long-running product line with broad availability of accessories and service know‑how.
Installation & Maintenance
- Mounting environment – Use a rigid 2-inch pipe or wall bracket; allow airflow around the housing and avoid direct radiant heat.
- Wiring – Route twisted pair in shielded cable; ground at one point only to minimize noise. Seal conduit entries with appropriate glands.
- Sensor leads – For RTDs, match 2/3/4‑wire configuration in the transmitter; keep leads as short and balanced as practical.
- Commissioning – Configure via HART handheld or asset software; verify LRV/URV, units, damping, and upscale/downscale failure mode.
- Routine care – Visual inspection quarterly; verify calibration yearly (or per QA policy). Firmware updates can be applied during planned outages.
- Safety – De‑energize the loop before opening covers in hazardous areas unless the approval permits; maintain gasket integrity to keep the IP rating.
Quality & Certifications
- CE, RoHS-compliant build (region dependent); manufacturer is ISO 9001 certified
- ATEX / IECEx / FM / CSA hazardous location approvals available by option
- SIL-capable configurations for safety instrumented systems (when specified)
- Manufacturer’s limited warranty is typically multi‑year for this series; our supply warranty is 365 days
Related Components (commonly paired)
- ROSEMOUNT 0085/0086 RTD and thermocouple sensor assemblies with thermowells
- ROSEMOUNT X-well Technology surface measurement assemblies (where no thermowell is preferred)
- Mounting brackets, sunshades, transient surge protection, and local indicator options










Reviews
There are no reviews yet.