Description
EMERSON VE3051C0 – DeltaV S‑series Analog Input (HART) Module for Reliable Process Measurements
The EMERSON VE3051C0 is part of the DeltaV S‑series I/O family, typically used as an 8‑channel 4–20 mA analog input module with HART pass‑through. It’s designed for stable, noise‑resistant signal acquisition from transmitters across process plants—think pressure, flow, level, and temperature loops. From my experience, this model is chosen when teams want straightforward commissioning, channel‑by‑channel diagnostics, and seamless HART device access through the DeltaV system.
Customer note: “We dropped the VE3051C0 into an existing S‑series cabinet and were trending HART data within the hour. The hot‑swap behavior made our turnaround window much less stressful.”
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery time: 1 week if in stock; no more than one month at the latest
- Payment terms: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- 8‑channel 4–20 mA AI – Suited for common process transmitters; typically supports single‑ended inputs with channel fault detection.
- Integrated HART pass‑through – Access device diagnostics, tags, and configuration from DeltaV workstations without extra multiplexers.
- S‑series hot‑swappable design – Replace the module under power to minimize downtime during maintenance.
- Per‑channel status and diagnostics – You might notice faster troubleshooting thanks to built‑in indicators and system diagnostics.
- System‑backplane powered – Power is supplied via the S‑series carrier, keeping cabinet wiring clean and consistent.
- “C0” variant – Typically denotes standard finish (non‑coated); useful when your cabinet environment is controlled and dry.
- Redundancy compatible – Often paired with an “S2” redundant configuration for high‑availability applications.
Technical Specifications
| Brand / Model | EMERSON VE3051C0 (DeltaV S‑series) |
| HS Code | 8538.90.00 (Parts for switching/controlling apparatus) |
| Signal Input Types | 4–20 mA analog inputs; HART protocol pass‑through (typical) |
| Number of Channels | 8 channels (typical for VE3051 family) |
| Input Range & Resolution | 4–20 mA; 16‑bit effective resolution (typical) |
| Communication Interfaces | Backplane to DeltaV controller; HART accessible via system tools (no external comm ports on the module) |
| Power Requirements | Supplied via S‑series backplane; approx. 24 VDC system power, ~3 W typical module consumption |
| Operating Temperature | 0 to +55 °C (32 to 131 °F) typical for S‑series I/O modules |
| Dimensions & Weight | Approx. 130 × 50 × 100 mm; ~0.25–0.35 kg (module form factor) |
| Installation Method | S‑series carrier/backplane mounting; hot‑swappable; front screw‑terminal connections via I/O base |
Related or Supporting Products
- EMERSON VE3051S2 – Similar AI/HART module with redundancy pairing (S2), typically used where high availability is required.
- EMERSON VE3052C0 – Analog Output (AO) module, often paired when loops require valve control or actuator drive.
- EMERSON VE3053C0 / VE3054C0 – Digital Input / Digital Output modules for discrete signals in the same S‑series cabinet.
- EMERSON VE4003S2T1 – DeltaV controller module; required to execute control strategies and manage I/O scanning.
- EMERSON VE4006P2 – S‑series system power supply; stable 24 VDC distribution to I/O and controller backplanes.
Installation & Maintenance
- Cabinet environment: Keep ambient within 0–55 °C, 5–95% RH non‑condensing. Provide ventilation or forced air if cabinet density is high.
- Mounting: Fit the VE3051C0 onto the S‑series carrier/backplane. Tighten retaining hardware and confirm the module locks fully into the connector.
- Wiring: Use shielded twisted pair for 4–20 mA and maintain proper grounding. Separate low‑level analog cables from AC and high‑current lines.
- Loop checks: After installation, perform per‑channel loop checks. You might notice faster commissioning when using DeltaV HART tools to verify device tags and ranges.
- Safety: De‑energize field loops before moving wiring. The module is hot‑swappable, but field wiring mistakes still trip protection or cause nuisance faults.
- Maintenance: Quarterly visual inspection for connector seating and terminal torque; clean dust with dry air; review diagnostics; schedule firmware updates during planned outages.
- Spare strategy: In most cases, one spare per cabinet row is sufficient; critical loops may justify a ready redundant set (S2 pairing).
Quality & Certifications
- Certifications: CE; UL/CSA industrial control equipment; RoHS compliant (typical for DeltaV S‑series modules).
- Manufacturer warranty: Typically 1 year when purchased new via authorized channels.
- Traceability: Modules ship with identifiable labels/serials; retain these for lifecycle documentation and revision tracking.
If you’re migrating or expanding, the VE3051C0 seems to be a safe choice where you want dependable analog acquisition plus HART visibility without complicating the cabinet. One thing I appreciate is how predictable the behavior is during hot swaps—less drama during turnarounds.







Reviews