Description
Emerson VE4005S2B1 DeltaV S-series Traditional I/O – 2‑wide base for reliable field wiring and system backplane connectivity
The Emerson DeltaV S‑series Traditional I/O platform is built around modular carriers and bases. The VE4005S2B1 is typically used as a 2‑wide S‑series Traditional I/O base/carrier, providing the mechanical DIN‑rail mount, field terminal interface, and backplane connection for S‑series DI/DO/AI/AO cards. From my experience, this model is chosen when you need a compact, serviceable base that keeps field wiring tidy and supports fast card swaps with minimal downtime.
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than 1 month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- 2‑wide S‑series base – Optimized footprint for two adjacent Traditional I/O positions, saving panel space on standard DIN rails.
- Backplane integration – Provides the DeltaV I/O bus and power pass‑through to the installed S‑series modules, simplifying wiring.
- Field‑wiring terminals (B1 style) – Screw‑clamp terminals support clean, serviceable connections; you might notice troubleshooting goes faster.
- Hot‑swap friendly design – In many cases, S‑series cards can be replaced without removing field wiring, reducing downtime during maintenance.
- Supports mixed I/O types – Works with Traditional I/O cards for DI/DO/AI/AO; HART pass‑through available when paired with suitable AI/AO modules.
- Robust build for industrial panels – Typically rated for control room environments with dependable mechanical retention and labeling options.
Technical Specifications
| Brand / Model | Emerson DeltaV – VE4005S2B1 (S‑series Traditional I/O base/carrier, 2‑wide) |
| HS Code | 8537.10 (Boards/panels for electric control, for a voltage ≤1000 V) |
| Power Requirements | Supplied via DeltaV S‑series backplane; 24 VDC system power (module‑dependent consumption) |
| Dimensions & Weight | S‑series 2‑wide DIN‑rail footprint; compact panel depth; weight typically < 0.6 kg |
| Operating Temperature | 0 to 55°C typical control room range (non‑condensing) |
| Signal I/O Types | Depends on installed modules: DI/DO (24 VDC), AI/AO (4–20 mA, HART-supported when applicable) |
| Communication Interfaces | DeltaV S‑series I/O backplane connection to controller via the carrier/base |
| Installation Method | DIN‑rail mounting, tool‑assisted locking; front access to field terminals (B1 style) |
Application Fields
Plants that standardize on DeltaV S‑series typically deploy this base wherever traditional field I/O needs a rugged, maintainable footprint:
- Oil & Gas – wellhead skids, compressor stations, and tank farms with mixed DI/DO and analog loops
- Chemicals & Petrochem – interlocks, valve actuation, and HART-enabled transmitters on existing marshalling
- Power Generation – balance‑of‑plant controls and retrofit panels with limited space
- Pharma & Life Sciences – clean panel builds where quick module swap matters for downtime
- Water & Wastewater – distributed cabinets with straightforward 24 VDC discrete I/O
Advantages & Value
- Reliability – Mechanical stability and proven S‑series signaling; fewer intermittent faults during shutdowns.
- Compatibility – Works with the broad range of DeltaV Traditional I/O modules; easy to match existing BOMs.
- Maintenance savings – Hot‑swap friendly approach typically cuts mean time to repair and avoids re‑terminating field wires.
- Lifecycle support – Emerson’s strong spares availability and documentation help procurement plan long‑term.
A maintenance supervisor told us, “We replaced an analog output card on a VE4005S2B1 base during operation—no rewire, no drama. That alone saved us a few hours per event.”
Installation & Maintenance
- Cabinet standards – Mount on 35 mm DIN rail inside a grounded metal enclosure; allow front clearance for cable bend radius and labeling.
- Ventilation – Maintain ambient 0–55°C; provide panel ventilation to keep air moving across the I/O stack.
- Wiring – Use properly sized shielded cables for analog; segregate DI/DO and AI/AO to reduce noise; maintain clean grounding practice.
- Safety – De‑energize affected circuits before adding/removing modules; verify correct keying/position to prevent mis‑mating.
- Routine upkeep – Periodically re‑torque terminal screws, inspect for oxidation, vacuum dust; apply firmware updates to the controller/I/O modules as recommended by Emerson.
Quality & Certifications
- Designed for industrial control panels; typically meets CE requirements
- UL/CSA recognition for control equipment (model‑family dependent)
- RoHS compliant materials
- Manufacturer’s warranty support available; sales warranty: 365 days
Commonly Paired Components
- DeltaV S‑series Traditional I/O modules (DI, DO, AI, AO; HART variants)
- DeltaV System Power Supply (24 VDC) and controller baseplates
- Shielded terminal kits, labeling strips, and DIN‑rail end stops for neat marshalling










Reviews