Description
FOXBORO FBM201 (RH914SQ) – Analog Input Fieldbus Module for I/A Series DCS
The FOXBORO FBM201, often referenced with catalog/revision code RH914SQ, is a staple analog input module in I/A Series / EcoStruxure Foxboro DCS installations. From my experience, it’s typically used to bring in 4–20 mA process signals from transmitters across the plant, with stable measurement quality and long lifecycle support. You might notice that it drops straight into the Series 200 baseplate, keeps wiring simple via the appropriate termination assembly, and just runs. That’s usually what maintenance teams want.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment, full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- Process analog inputs (4–20 mA) – Designed for bringing field transmitter signals into the DCS reliably. In many cases, channels are isolated for noise immunity and plant safety.
- Series 200 baseplate compatible – Plugs onto the standard FBM baseplate, so swaps and expansions are fast without panel rework.
- High signal stability – From what users report, readings remain steady even in electrically noisy areas, which helps with control loop tuning.
- Field wiring via dedicated TA/FTA – Clean separation of I/O and electronics; easier troubleshooting and faster turnarounds during outages.
- Modulebus integration – Communicates over the Foxboro Modulebus to the controller, avoiding additional gateways.
- Lifecycle-fit for installed base – Ideal for brownfield replacements; keeps your control strategy intact with minimal engineering changes.
Technical Specifications
| Brand / Model | FOXBORO FBM201 (RH914SQ) |
| HS Code | 8538.90 (Parts suitable for industrial control equipment) |
| Power Requirements | 24 VDC supplied via Series 200 FBM baseplate; typical module consumption approx. 2–3 W |
| Dimensions & Weight | Standard Series 200 FBM footprint; compact plug-in module, typical weight under 0.5 kg |
| Operating Temperature | Typically 0 to +60 °C; 5–95% RH non-condensing (plant standard) |
| Signal Input/Output Types | Analog Input, 4–20 mA; channel isolation and HART pass-through may depend on module revision—confirm per lot |
| Communication Interfaces | Foxboro Modulebus via Series 200 baseplate to the DCS controller |
| Installation Method | Plug-in FBM on Series 200 baseplate; field wiring via matching termination assembly (TA/FTA); cabinet/DIN-rail baseplate mounting |
Application Fields
This module fits where robust 4–20 mA acquisition is needed. We typically see it in:
- Oil & Gas (wellhead pressure, separator levels, produced water monitoring)
- Chemical & Petrochemical (reactor temperature/pressure via transmitters, utility balances)
- Power Generation (boiler draft, feedwater, condenser vacuum transmitters)
- Water & Wastewater (flow, turbidity, dissolved oxygen via 4–20 mA analyzers)
- Pharma & Food (CIP/SIP skids, tank levels, hygienic pressure transmitters)
Advantages & Value
- Reliability in harsh panels – The Series 200 design is proven; fewer nuisance trips and clean signal handling in most cases.
- Compatibility with installed base – Keeps your controller and engineering database unchanged; easy hot swap with matching TA pinout.
- Cost control – Minimal rewiring, no extra gateways, and short commissioning time usually means lower outage costs.
- Support and lifecycle – We can advise on mixed-channel strategies, spare holding, and revision compatibility to avoid surprises.
Installation & Maintenance
- Panel & environment – Install on the Series 200 baseplate in a ventilated cabinet; allow airflow around modules; avoid high vibration and corrosive atmospheres.
- Wiring – Use the correct TA/FTA and shielded twisted pairs for 4–20 mA runs. Ground shields at one end to reduce noise.
- Power – Feed the baseplate with clean 24 VDC; redundant supplies where available. Check load budget when adding channels.
- Safety – De-energize the baseplate before inserting/removing modules unless hot-swap is specified for your setup. Follow plant LOTO practices.
- Routine care – Periodically verify loop calibrations, inspect connectors for looseness, and review diagnostics in your DCS. Firmware updates (when applicable) should follow site MOC procedures.
Quality & Certifications
The FBM201 platform is typically supplied with CE marking and UL/CSA listings for industrial control equipment. RoHS compliance may depend on production batch and revision; we can confirm against the specific serial number you’re sourcing. Manufacturer warranty practices vary by channel; our coverage is 365 days as stated above.
Common Supporting Components
- Series 200 FBM Baseplates (2/4/8-wide) – Provide power and Modulebus connectivity for FBM201 and peers.
- Termination Assemblies (TA/FTA) – Field wiring interface for 4–20 mA loops; choose the TA that matches your channel isolation and HART needs.
- Pre-terminated Cables – Reduce panel time and wiring errors, especially on turnaround schedules.
- Redundant Power Supplies – For higher availability panels feeding multiple FBMs.
If you’re replacing an existing FBM201, share the exact part/revision code on the side label (RH914SQ here) and the TA model you’re using. Matching those details typically ensures a painless drop-in with no DCS reconfiguration.







Reviews