Description
GE IC754VSI06STD-LH – Compact 6-inch QuickPanel View HMI for reliable machine operation
The IC754VSI06STD-LH is part of the GE QuickPanel View family—a compact, 6-inch-class touchscreen HMI built for everyday operator tasks like setpoint changes, alarm acknowledgment, and basic trending. From my experience, this size is a sweet spot for skids, small packaging cells, and pump stations where cabinet space is tight but you still want Ethernet connectivity and a bright, easy-to-read display. The “LH” variant is typically an LED-backlit, high-brightness model, which seems to be favored in areas with variable lighting or when you want longer backlight life.
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- 6-inch-class color TFT touchscreen – A compact footprint that still gives operators clear access to pages, alarms, and recipes.
- LED high-brightness (LH variant) – Typically provides better visibility and longer backlight life than older CCFL designs.
- Industrial 24 VDC power – Simple to integrate with standard control panels.
- Integrated Ethernet + serial ports – Commonly used with Modbus TCP/RTU and GE SRTP; useful when you’re bridging older serial devices to a modern network.
- USB host/device – Handy for firmware updates, data transfer, or a USB keyboard during commissioning.
- CompactFlash storage – In many cases used for data logging, recipe files, and project backups.
- Panel-mount, IP65 front – You might notice the sealed bezel holds up well in dusty environments when installed with the gasket.
- Configured with Proficy Machine Edition (View) – Streamlines changes and reuse across your GE/Emerson HMI projects.
Technical Specifications
| Brand / Model | GE QuickPanel View – IC754VSI06STD-LH |
| HS Code | 8537.10 (boards/panels for electric control, ≤1000V) |
| Display | 6-inch-class color TFT LCD, LED backlight (LH variant); resistive touch |
| Power Requirements | 24 VDC nominal (typically accepts ~20.4–28.8 VDC) |
| Operating Temperature | 0 to 50 °C (typical for this series) |
| Communication Interfaces | 10/100Base‑T Ethernet (RJ‑45); Serial ports (RS‑232/RS‑485); USB host & device |
| Signal I/O Types | HMI interface only (no onboard discrete/analog I/O); connects to PLCs via drivers |
| Storage / Expansion | CompactFlash slot; USB for data transfer and maintenance |
| Software Environment | Configured with Proficy Machine Edition – View |
| Installation Method | Panel mount with gasket and mounting clips; IP65-rated front when properly installed |
Where it fits best
Typical deployments include OEM skids, compact packaging machines, dosing stations, and small process panels. One packaging integrator told us they replaced an aging 5.7-inch HMI with this unit and kept the existing Ethernet/RS‑485 wiring—commissioning was a half‑day job because the drivers in Proficy covered their PLC mix without surprises.
Related or Supporting Products
- IC754VSI06CTD – Similar 6-inch QuickPanel View variant; typically same communications with a different display/backlight option.
- IC754VGI06STD – “Control” variant that, in many cases, adds integrated logic control capabilities alongside the HMI.
- IC755CWE07CDA (QuickPanel+ 7″) – Modern replacement path with higher resolution and a faster platform when you’re standardizing on newer HMIs.
- Accessories – Industrial CompactFlash card (for data/recipes), shielded RS‑485 cable, Cat5e/6 patch leads, 24 VDC DIN‑rail power supply (30–60 W range is typical), replacement panel gasket, and mounting clips.
Installation & Maintenance
- Cabinet & mounting – Use a rigid panel door; cutout per the manual; install the gasket evenly and torque clips uniformly to maintain the IP65 front seal.
- Power & grounding – Supply clean 24 VDC with proper overcurrent protection; bond the HMI chassis ground to the panel ground to reduce noise issues.
- Wiring – Keep Ethernet and serial signal cables separate from power lines; for RS‑485, use shielded twisted pair and terminate at the network ends only.
- Ventilation – Provide airflow around the rear heat sink; avoid mounting above heat-generating drives without a heat shield or ducting.
- Maintenance – Periodically back up the project (CF or USB), clean the bezel with a non‑abrasive cloth, and review event/alarm logs. Firmware updates can typically be applied via USB or Ethernet when scheduled downtime is available.
- ESD & safety – Observe ESD precautions during handling; de‑energize the circuit before changing CF cards or cabling.
Quality & Certifications
- Typically CE and UL/cUL compliant for industrial control equipment
- RoHS compliant in most cases for this series
- Manufacturer’s standard quality processes applicable to QuickPanel View family
- Our warranty coverage: 365 days from shipment
If you’re replacing an older QuickPanel or consolidating a small operator station, the IC754VSI06STD-LH usually drops in with minimal rewiring. Tell us your PLC brand and protocols, and we’ll confirm driver support and lead time.