Description
GE IC755CSS06RDA QuickPanel+ HMI – Compact 6-inch resistive touchscreen for reliable machine operation
The GE IC755CSS06RDA is a 6-inch QuickPanel+ operator interface designed for tight panels and glove-friendly use on the factory floor. From my experience, this size lands well on OEM skids, compact packaging machines, pump stations, and retrofit panels where you still want Ethernet and serial connectivity without giving up precious door space. It typically runs on 24 VDC, offers a bright TFT display, and uses a resistive touchscreen—great when operators are wearing standard gloves.
You might notice that QuickPanel+ units are valued for straightforward integration with PACSystems as well as third‑party PLCs via common industrial protocols. The IC755CSS06RDA follows that pattern, with Ethernet for plant networks and serial for legacy gear, plus USB for project loading or data export. It seems to be a sensible pick when you need a durable, panel‑mount HMI with a small footprint and familiar GE tooling.
Order Placement Process & Guarantees
-
- – Warranty period: 365 days
-
- – Delivery: 1 week if in stock; no more than one month at the latest
-
- – Payment terms: 50% advance payment; full payment prior to delivery
- – Express delivery options: FedEx, UPS, DHL
Key Features
- 6-inch resistive touchscreen – Responsive with gloved hands; typically favored in washdown or maintenance-heavy areas.
- Industrial 24 VDC power – Standard panel supply, reduces wiring complexity on OEM machines.
- Ethernet + serial connectivity – Usually supports 10/100 Ethernet and RS‑232/485 for both modern and legacy PLCs.
- USB and removable media support – Handy for recipe transfers, firmware updates, or on-site backups.
- Panel‑mount, sealed front – When properly installed, the front bezel is typically rated for industrial environments (IP/NEMA grade), helping it survive in dusty or damp panels.
- QuickPanel+ software ecosystem – Works with GE’s engineering tools for faster project deployment and common drivers like Modbus TCP/RTU in many cases.
- Compact depth – Fits shallow enclosures; a practical choice for door-dense MCCs and space-limited machine frames.
Technical Specifications
| Brand / Model | GE QuickPanel+ / IC755CSS06RDA |
| HS Code | 8537.10 (Industrial control panels / operator interfaces) |
| Power Requirements | 24 VDC nominal (typical for QuickPanel+ series) |
| Display & Touch | 6-inch TFT; resistive touch (glove-friendly) |
| Operating Temperature | Typically 0 to 55 °C (refer to datasheet for exact rating) |
| Signal Input/Output Types | Touch input only; no onboard discrete/analog I/O |
| Communication Interfaces | 1x 10/100 Ethernet, RS‑232/RS‑485 (multi‑mode), USB Host/Device; microSD slot (typical for series) |
| Installation Method | Panel mount with gasket and clips; front bezel typically IP65/66 when correctly installed |
| Dimensions & Weight | Compact 6-inch form factor; shallow depth for tight enclosures; weight typically under 1 kg |
Related or Supporting Products
- IC755CSS06CDA – Similar 6″ unit with capacitive touch (multi‑touch gestures; not as glove-friendly).
- IC755CSW07CDA – 7″ widescreen QuickPanel+, more screen real estate in nearly the same cabinet depth.
- IC755CSS10RDA – 10″ resistive model when operators need larger buttons at distance.
- Proficy Machine Edition – Engineering software for HMI configuration and PLC communications drivers (e.g., Modbus TCP/RTU, among others).
- PACSystems RX3i / RXi Controllers – Common PLC pairing over Ethernet; also works with many third‑party PLCs via drivers.
- 24 VDC Industrial Power Supply – Use a regulated supply sized for HMI inrush and peripheral loads.
Installation & Maintenance
- Cabinet & mounting – Panel-mount on a flat, rigid door with the supplied gasket; follow the cutout to avoid bezel stress. Keep clear airflow around the rear housing.
- Environment – Aim for clean, dry enclosures meeting IP54 or better; avoid direct steam or abrasive dust. Front sealing reaches its rating only when properly installed.
- Power & wiring – 24 VDC regulated, with proper grounding. Use ferrules on field wiring. For RS‑485, use shielded twisted pair and terminate at the bus ends.
- Networking – Use industrial-rated Ethernet cables; segment control traffic where possible. Static IP addressing is common for HMIs on machine-level networks.
- Touchscreen care – Resistive screens can be calibrated in software. Clean with a lint-free cloth and mild cleaner; avoid solvents that could haze the lens.
- Backups & updates – Keep the HMI project and firmware aligned. Routine backups to USB or SD make replacements painless in most cases.
- Spare strategy – For 24/7 lines, keeping a same-size spare panel saves hours; the 6″ footprint is quick to swap.
Quality & Certifications
- CE and UL/cUL listed for industrial use (typical for QuickPanel+ series; confirm exact file on the datasheet if needed).
- RoHS compliance in many regions.
- Manufacturer’s standard quality processes (ISO-based production).
- Store warranty: 365 days from delivery.





Reviews
There are no reviews yet.