Description
GE PACSystems RX3i IC694MDL931 – Discrete Input Module for reliable machine and line sensing
The IC694MDL931 is a PACSystems RX3i rack-mount discrete input module designed for high-uptime control systems. It slides into an RX3i rack, takes its power from the backplane, and brings field signals into the CPU with robust noise immunity and per‑point diagnostics. From my experience, it’s a straightforward, dependable choice when you need clean, channel‑level status visibility and stable input filtering in packaging, material handling, and process interlocks.
Order Placement Process and Guarantees
- Warranty: 365 days
- Lead time: 1 week if in stock; no more than 1 month latest
- Payment terms: 50% advance payment; full payment before delivery
- Shipping: FedEx, UPS, DHL (express options)
- Quality assurance: Parts are inspected and powered-on tested before dispatch, with traceable packing and ESD-safe handling.
Key Features
- RX3i rack integration – Plugs directly into the PACSystems RX3i backplane; no external power needed on the logic side.
- Per‑channel status LEDs – You might notice that troubleshooting on the panel door is faster since each input shows real‑time state.
- Input filtering – Typically includes configurable or built‑in debounce to reduce nuisance trips from contact bounce or electrical noise.
- Group commons and isolation – Field-to-logic isolation helps protect the CPU and adjacent modules in most cases.
- Diagnostics in PAC Machine Edition – Channel fault/status data appears clearly in PME, which makes commissioning smoother.
- High channel density – Suited for applications with lots of sensors and switches per cabinet footprint.
- Hot‑swap ready (rack dependent) – On RX3i, you can typically replace modules with minimal downtime when the system is designed for it.
Technical Specifications
| Brand / Model | GE PACSystems RX3i / IC694MDL931 |
| HS Code | 8537.10 (Programmable controllers and I/O assemblies) |
| Power Requirements | Supplied from RX3i backplane (5 VDC logic rail; low current draw typical for a single‑wide module) |
| Signal Input/Output Types | Discrete input module (logic-level field inputs with per‑channel status) |
| Communication Interfaces | Backplane interface to RX3i CPU; no front communication port |
| Operating Temperature | Typically 0 to 60 °C (32 to 140 °F) in a ventilated enclosure |
| Installation Method | Single‑wide module; installs in RX3i rack (panel‑mounted chassis); removable field terminal block |
| Dimensions & Weight | Standard RX3i single‑slot form factor; light/medium weight for discrete I/O module |
Related or Supporting Products
- IC695CPE330 – RX3i CPU with Ethernet; pairs well when you need modern networking and faster scan times.
- IC695PSD140 – RX3i power supply; stable 5 VDC backplane power for mixed I/O racks.
- IC695CHS012 – 12‑slot RX3i universal rack; good when you’re planning higher I/O counts.
- IC695PNC001 – PROFINET Controller for distributed I/O architectures.
- IC695ETM001 – Ethernet module for additional network interfaces where needed.
- Alternative I/O modules – If your project requires different signal types (e.g., AC inputs or transistor/relay outputs), there are sibling RX3i MDL variants with matching mechanics and diagnostics.
Installation & Maintenance
- Cabinet & environment – Mount the RX3i rack on a rigid backplate inside a ventilated enclosure. Keep ambient within 0–60 °C and 5–95% RH non‑condensing.
- Wiring – Use 60/75 °C copper conductors. Route field wiring away from high‑voltage lines; add ferrules where practical. Tighten terminal screws to the manufacturer’s torque spec to avoid intermittents.
- Shielding & grounding – For noisy environments, bond shields at a single point to panel ground. From my experience, a clean ground scheme reduces false transitions dramatically.
- Module handling – De‑energize the rack or follow approved hot‑swap procedure. Observe ESD precautions.
- Routine maintenance – Inspect terminals quarterly, re‑torque if needed, and clean dust filters. Review input filter settings during changeovers to match sensor behavior.
- Firmware/project updates – Keep the CPU firmware and PME project documentation aligned with actual module part numbers to maintain correct diagnostics.
Quality & Certifications
- Typically conforms to CE and UL/cUL listings for industrial control equipment.
- RoHS compliance is common for RX3i modules; documentation can be provided on request.
- Manufacturer quality system aligns with ISO standards for design and production.
- Store warranty: 365 days. Factory warranty terms may vary by region and build date; we support advance replacement in most cases subject to availability.
Quick field note: a maintenance lead from a beverage line told us the IC694MDL931 cut their fault‑finding time because the channel LEDs made it obvious when a sensor went marginal rather than a PLC logic issue. That seems to be the common win with this module—simple, reliable indication and steady inputs even on older wiring.