Honeywell 51304362-300 – I/O Termination Assembly for TPS/TDC Field Wiring51304362-300

The Honeywell 51304362-300 is a field-wiring termination board typically used in TPS/TDC 3000 architectures. In many cases it serves as the I/O Termination Assembly (IOTA) that bridges plant instruments to the associated I/O electronics. From my experience, teams choose it as a like-for-like replacement to keep existing marshalling and wiring intact, minimize downtime, and maintain full compatibility with installed Honeywell I/O processors.

One thing I appreciate is how these IOTA-style boards keep signal wiring tidy and serviceable—clear terminal labeling, robust screw clamps, and proven insulation spacing. You might notice that it behaves as a passive interface (no external power), which tends to simplify commissioning and long-term maintenance.

Company’s Order Placement Process and Guarantees

  • Warranty period: 365 days
  • Delivery time: 1 week for in-stock items; no more than one month at the latest
  • Payment method: 50% advance payment; full payment prior to delivery
  • Express delivery methods: FedEx, UPS, DHL

Key Features

  • TPS/TDC ecosystem fit – Designed to work within Honeywell DCS cabinets, pairing with the appropriate I/O electronics.
  • Passive termination – No external power draw; reduces failure points and simplifies troubleshooting.
  • Field-proven wiring interface – Screw-clamp terminals and clear channel markings for fast, mistake-resistant hookups.
  • Service-friendly layout – Facilitates loop checks, channel isolation, and replacement during planned outages.
  • Consistent footprint – Typically matches standard Honeywell I/O carriers, keeping cabinet layouts unchanged.
  • ESD-safe construction – Industrial-grade PCB and components suitable for control-room environments.

Technical Specifications

Brand / Model Honeywell 51304362-300
HS Code 8538.90 (Parts suitable for apparatus of heading 8537)
Power Requirements Passive termination board; no external power input
Dimensions & Weight Standard Honeywell IOTA footprint; typically mid-density board in the 0.4–0.6 kg range (contact us for drawing)
Operating Temperature 0 to 55°C typical control-cabinet environment; 5–95% RH non-condensing (typical)
Signal Input/Output Types Field signal termination (AI/AO/DI/DO depending on paired I/O module); screw-clamp terminals
Communication Interfaces Internal edge/backplane connection to Honeywell I/O electronics; no external network ports
Installation Method Cabinet/carrier mounting in Honeywell DCS racks; wire via labeled terminal blocks

Application Fields

This model is commonly used in TPS/TDC-based control systems across oil & gas, petrochemical, chemical, power generation, pulp & paper, metals, and water/wastewater. Typical jobs include replacing worn termination boards during turnarounds, adding channels during small I/O expansions, and restoring loop integrity after cabinet refurbishments. A maintenance lead at a refinery mentioned it “dropped straight into the existing carrier, no rewiring headaches,” which seems to be the norm with these boards.

Advantages & Value

  • Like-for-like compatibility – Keeps existing cabinet layouts and loop documentation intact, reducing engineering time.
  • Short downtime – Passive design and familiar terminal layout speed up swap-outs during shutdowns.
  • Risk reduction – Genuine Honeywell form/fit lowers the chance of wiring errors and nuisance trips.
  • Lifecycle support – Suitable for sustaining TPS/TDC assets while larger migration plans are scheduled.
  • Technical backup – We can share wiring notes and typical torque values to help your team verify connections quickly.

Installation & Maintenance

  • Environment – Install in a clean, ventilated control cabinet within the specified temperature and humidity range. Avoid dust and corrosive atmospheres.
  • Mounting – Fit to the designated Honeywell carrier/rack positions; ensure all fixing screws are secure and the edge connector is fully seated.
  • Wiring – Use the labeled terminal channels; segregate analog, digital, and power cabling; maintain shield terminations as per site standards.
  • ESD and safety – De-energize affected loops, use ESD protection, and verify isolation before handling conductors.
  • Routine checks – Periodically inspect for loose terminals, discoloration, or damaged insulation; re-torque terminals during outages and clean with an ESD-safe brush or dry air.
  • Firmware note – The termination board itself is passive; if paired I/O electronics are replaced, confirm firmware compatibility at the I/O processor level.

Quality & Certifications

  • Manufacturing typically aligned with ISO 9001 processes
  • CE conformity and RoHS status available for most TPS/TDC assemblies (varies by revision)
  • UL/CSA recognition may apply to specific module families and regions
  • Vendor warranty: 365 days from delivery

Related/Supporting Components

The 51304362-300 is typically used alongside Honeywell I/O processors and carriers in TPS/TDC systems, such as Analog Input (AI), Analog Output (AO), Digital Input (DI), or Digital Output (DO) I/O modules. Common accessories include carrier backplanes, shield bars, and field cable assemblies. If you share your current rack layout or a cabinet photo, we can suggest the exact mates and any jumper or shield kit that tends to be required.

Reviews

There are no reviews yet.

Be the first to review “Honeywell 51304362-300 – I/O Termination Assembly for TPS/TDC Field Wiring”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products