Honeywell 51304453-100 – Field I/O Termination Assembly for TDC 3000 / Experion PKS Cabinets
The Honeywell 51304453-100 is commonly used as a Field Terminal Assembly (FTA) in Honeywell TDC 3000/TPS and Experion PKS systems, providing a clean, reliable termination point between field wiring and the associated Honeywell I/O module. From my experience, teams lean on this part during brownfield expansions and maintenance turnarounds because it drops into existing marshalling layouts with minimal rework. You might notice that it keeps wiring straightforward—field on one side, multi‑pin system cable on the other—so troubleshooting stays simple.
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock, no more than one month at the latest
- Payment: 50% advance payment; full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- Purpose-built for Honeywell I/O – Interfaces field signals to Honeywell I/O modules typically used in TDC 3000/TPS and Experion PKS racks.
- Clean marshalling – Screw terminal field connections on one side; multi‑pin system cable interface on the other for quick, traceable wiring.
- Passive design – In most cases no external power; fewer points of failure and easier maintenance.
- Signal versatility – Suits common analog (4–20 mA/0–10 V) and discrete I/O when paired with the correct Honeywell module; channel count and options depend on the specific I/O type used.
- Cabinet-friendly – Typically DIN rail or panel mount in standard marshalling cabinets; clear labeling helps technicians work faster.
- Lifecycle support – Often stocked as a like‑for‑like spare to cut downtime during swap-outs.
Technical Specifications
| Brand / Model | Honeywell 51304453-100 |
| HS Code | 8538.90 (Parts suitable for use with electrical control equipment) |
| Power Requirements | Typically none (passive termination; powered via associated I/O circuit as applicable) |
| Signal I/O Types | Compatible with analog (4–20 mA / 0–10 V) and discrete I/O, depending on the paired Honeywell I/O module |
| Communication Interfaces | Field screw terminals to multi‑pin IOTA/FTA cable connection for the system I/O module |
| Installation Method | DIN rail or panel mounting in marshalling cabinets (per Honeywell layout guidelines) |
| Operating Temperature | Typically cabinet ambient 0 to 55°C when installed to Honeywell environmental specs |
Application Fields
This model is widely used in process industries where Honeywell DCS platforms are standard. Typical deployments include:
- Refining and petrochemicals – analog/digital marshalling for instrument loops
- Chemicals and specialty materials – expansions or loop tie-ins during plant debottlenecking
- Power generation – retrofit work in balance‑of‑plant cabinets
- Water & wastewater – standardized marshalling in PLC/DCS hybrid panels
- Pharmaceuticals – clean wiring practices for validated systems
One thing I appreciate is how predictable the field terminations are during turnarounds; teams often comment that swapping to a fresh 51304453-100 gets them back online quickly without hunting through custom wiring diagrams.
Advantages & Value
- Reliability: Passive construction in many cases means fewer components to fail and stable long-term service.
- Compatibility: Designed around Honeywell I/O ecosystems—reduces adaptation hardware and engineering hours.
- Reduced downtime: Drop-in replacement approach speeds hot-cutover and maintenance activities.
- Cost control: Standardized part simplifies spares strategy across multiple cabinets and sites.
- Technical support: We can help confirm cable part numbers and I/O pairing to avoid mismatches.
Installation & Maintenance
- Cabinet standards: Install in a clean, ventilated marshalling cabinet; follow Honeywell clearances and grounding practices.
- Wiring: Separate analog and discrete bundles where practical; terminate cable shields per site earthing rules; torque terminals to spec.
- Cabling to I/O: Use the correct Honeywell multi‑pin cable for the paired I/O module (IOTA/FTA type). Label both ends for traceability.
- Safety: Isolate power and verify loop de‑energization before moving any field conductors; use lockout/tagout.
- Routine checks: Periodically re‑tighten terminals, inspect for corrosion or insulation damage, and clean dust with dry air.
- Calibration & firmware: The FTA itself has no firmware; any calibration remains with the transmitter or I/O module.
Quality & Certifications
- Manufactured to Honeywell’s industrial control standards; CE/UL conformity typically available for cabinet components
- RoHS compliance in many cases for current production and certified refurb lines
- Backed by a 365‑day warranty from shipment