HONEYWELL 90088-A-9001 – OEM Control Module for Honeywell Process Systems

1 Brand: HONEYWELL
2 Model: 90088-A-9001
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

HONEYWELL 90088-A-9001 – OEM Control Module for Honeywell Process Systems90088-A-900190088-A-9001-2

The HONEYWELL 90088-A-9001 is an original Honeywell board-level module used in industrial control environments where downtime is costly and long-term system stability matters. From my experience, this model typically serves as a plug-in card within a Honeywell rack or node, drawing power and signaling through the backplane to interface with the controller and I/O subsystem. If you’re maintaining a Honeywell DCS node or upgrading a mixed-generation system, this part seems to be a practical, drop-in replacement that helps you keep your installed base running to spec.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days coverage from delivery date
  • Delivery time: 1 week when in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL
  • Pre-shipment checks: visual inspection, packaging verification, and powered functional test when applicable

Key Features

  • OEM Honeywell module – Sourced as genuine Honeywell hardware to protect system compatibility and lifecycle plans.
  • Backplane-powered plug-in design – Installs into the Honeywell chassis slot; no external field power needed in most cases.
  • Industrial-grade build – Typically conformal-coated PCB and robust connectors for plant environments with vibration and electrical noise.
  • Stable operation – Designed to run continuously in 24/7 process control service with consistent signaling and timing.
  • Service-friendly – Clear labeling and standard Honeywell latching/guide rails simplify swap-outs during scheduled maintenance.
  • Traceability & handling – ESD-safe packaging and serial trace support to align with QA procedures.

Technical Specifications

Brand / Model HONEYWELL 90088-A-9001
HS Code 8538.90 – Parts suitable for apparatus of heading 8537 (industrial control panels/modules)
Power Requirements Backplane powered; typically uses system 5 VDC (and, where applicable, ±12 V rails) from the Honeywell node power supply
Dimensions & Weight Plug-in PCB assembly for Honeywell rack slot; card form factor consistent with Honeywell chassis guides
Operating Temperature Typically 0 to +55 °C when installed in a ventilated control cabinet
Signal I/O Types Interfaces through the Honeywell backplane; field I/O handled via the system’s terminal assemblies depending on configuration
Communication Interfaces Proprietary Honeywell backplane bus; no direct Ethernet/serial port on the module face in most applications
Installation Method Rack-mounted, plug-in card with guide rails and locking levers; ESD precautions required

Application Fields

You might notice that this part shows up most in continuous-process environments. Typical use cases include:

  • Chemical and petrochemical units maintaining legacy Honeywell nodes
  • Refining and pipelines where control room downtime is tightly scheduled
  • Power generation (cogen, combined-cycle) sustaining mixed-generation DCS assets
  • Pharmaceuticals and food processing lines with validated Honeywell control infrastructure
  • Pulp & paper and water treatment plants maintaining stable process loops

A maintenance lead at a cogeneration site told us, “Swapping in the 90088-A-9001 was straightforward—no wiring changes, just reseat, power-up, and the node came clean on diagnostics.”

Advantages & Value

  • Reliability: OEM hardware helps reduce nuisance trips and intermittent bus faults.
  • Compatibility: Drop-in fit for the intended Honeywell chassis, minimizing engineering time.
  • Cost control: Short lead-times in many cases cut outage duration and contractor costs.
  • Technical support: Pre-shipment checks and post-install guidance if addressing/position settings are involved.

Installation & Maintenance

  • Cabinet environment: Install in a clean, ventilated control cabinet; keep ambient within the cabinet’s specified limits (typically 0–55 °C).
  • Power isolation: De-energize the node and discharge residual energy before removing/inserting the module.
  • ESD handling: Use a grounded wrist strap and handle the board by the edges only.
  • Seating & guides: Align with the card guides; apply even pressure to seat the edge connector fully and engage latches.
  • Address/settings: If the slot requires DIP/rotary addressing, match the previous module’s settings before power-up.
  • Routine checks: Inspect connectors during planned outages; verify node diagnostics; keep firmware/configuration backups current where applicable.
  • Cleaning: Dust the cabinet and intake filters; avoid solvents—use dry, ESD-safe wipes.

Quality & Certifications

  • CE and UL conformity are typical for Honeywell control modules used in industrial panels.
  • Manufacturing quality aligned with ISO 9001 practices.
  • RoHS status can vary by production vintage; we can verify per serial/lot on request.
  • 365-day warranty; each unit is packaged with ESD protection and undergoes functional verification where applicable.