Meggitt Vibro-Meter VM600 IOC8T – 8-channel transducer I/O for high-integrity machine condition monitoring

1 Brand: Vibro-Meter
2 Model:VM600 IOC8T
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Meggitt Vibro-Meter VM600 IOC8T – 8-channel transducer I/O for high-integrity machine condition monitoringVM600-IOC8T

The VM600 IOC8T is an 8-channel input/output (transducer) module for the Vibro-Meter VM600 rack. From my experience, it’s the piece that makes sensor wiring practical and reliable on critical assets—turbines, large compressors, and balance-of-plant machines. It typically provides the sensor termination, transducer power, and buffered outputs your protection and condition monitoring cards need, without adding complexity to the rack.

You might notice that plants use IOC8T modules when they want tidy, serviceable field wiring and consistent signal quality across multiple channels. It pairs with VM600 monitoring/protection cards (for example XMV16 or MPC4, depending on the rack configuration), giving you a straightforward way to bring in accelerometers, proximity probes, or velocity sensors and get clean buffered signals for diagnostics.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week for in-stock items; no more than one month at the latest
  • Payment: 50% advance payment, full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Eight transducer channels – Brings in up to 8 sensors per module; ideal for multi-bearing machines or grouped assets.
  • Sensor power and termination – Typically supports IEPE/ICP accelerometers, eddy-current proximity probes (via appropriate drivers), and velocity pickups; keeps wiring clean and consistent.
  • Buffered analog outputs – Front-access buffered outputs per channel for portable analysis, trending, or route data capture.
  • Tight integration with VM600 cards – Works within the VM600 rack, linking sensors to monitoring/protection modules like XMV16 or MPC4 via the backplane.
  • Rack-powered, no external PSU – Draws power from the VM600 backplane, which reduces cabinet clutter and wiring points.
  • Service-friendly front panel – Technicians can access test points and verify signals without disturbing field terminations.
  • Industrial reliability – Built for continuous operation in control panels near rotating equipment, with stable performance in most plant environments.

Typical Use Cases

  • Gas/steam turbine trains where multiple proximity and vibration channels feed a protection card for trip logic.
  • Large compressors and expanders in refining or petrochemical units needing consistent IEPE accelerometer wiring and buffered outputs for specialists.
  • Balance-of-plant pumps, motors, and fans monitored via velocity or accelerometer sensors, grouped to reduce rack slot count.

Technical Specifications

Brand / Model Meggitt Vibro-Meter VM600 IOC8T
HS Code 9031.80 (Measuring/monitoring instruments, other)
Power Requirements Powered via VM600 rack backplane; no external power supply typically required
Dimensions & Weight VM600 plug-in board (6U Eurocard format); standard single-slot front panel; lightweight module
Operating Temperature Typically 0 to +55 °C (control cabinet environment), non-condensing humidity
Signal Input/Output Types 8 transducer inputs (e.g., IEPE accelerometer, proximity probe, velocity sensor) with per-channel buffered analog outputs
Communication Interfaces Backplane interface within VM600; no external fieldbus/ethernet on IOC8T
Installation Method Pluggable module for VM600 19-inch rack; front-access terminals/BNC for field wiring and buffered outputs

Related or Supporting Products

  • VM600 XMV16 – 16-channel dynamic measurement card; in many cases used with IOC8T modules to handle large channel counts.
  • VM600 MPC4 – 4-channel machine protection card for trip logic; typically paired with IOC-type I/O modules for sensor interfacing.
  • VM600 IOC4T – 4-channel transducer I/O module; suitable when fewer channels per slot are needed or for smaller machines.
  • VM600 CPUM – Rack CPU/communications module enabling data collection, configuration, and system communications.
  • VM600 RLC or relay modules – For discrete relay outputs when you need hardwired alarms/trips to DCS or interlocks.

A maintenance lead told us the IOC8T “made our route data easier—techs can clip onto the buffered outputs without touching the field terminations,” which seems to be the small convenience that saves time during outages.

Installation & Maintenance

  • Cabinet & environment: Mount the VM600 rack in a 19-inch enclosure, typically at 6U height with adequate ventilation. Keep ambient temperature within the specified control-room range and avoid high-vibration panels.
  • Wiring practices: Use shielded cables for vibration and proximity signals; ground shields at one end to minimize noise. Separate transducer wiring from high-voltage or VFD cabling.
  • Power & backplane: Ensure the rack power supply capacity covers all installed modules; modules draw power from the backplane, so no separate PSU is usually needed for IOC8T.
  • Safety: De-energize the rack before inserting/removing modules. Observe ESD precautions—handle cards by edges and use an ESD wrist strap.
  • Routine maintenance: Periodically verify sensor bias/loop health, wipe dust from front panels, and check terminal tightness. Firmware/config updates are performed on the VM600 processing/CPU cards as applicable.
  • Calibration & checks: In most cases, channel verification with portable calibrators or reference signals during outages keeps confidence high without removing field wiring.

Quality & Certifications

  • Manufacturer quality system typically certified to ISO 9001
  • CE marking for EMC and safety compliance
  • RoHS compliance for hazardous substances
  • Manufacturer warranty supported; our sales warranty coverage: 365 days

If you’re standardizing on VM600, the IOC8T usually hits a sweet spot for multi-channel builds—fewer modules to manage, cleaner wiring, and easy access to buffered signals for diagnostics. Happy to help check slot counts and channel mapping based on your P&ID or instrument index.

Reviews

There are no reviews yet.

Be the first to review “Meggitt Vibro-Meter VM600 IOC8T – 8-channel transducer I/O for high-integrity machine condition monitoring”

Your email address will not be published. Required fields are marked *