NI SCXI-1163R – 32‑Channel Isolated Digital Input Module for 24 V Industrial Signals

Brand / Model NI (National Instruments) / SCXI-1163R
HS Code 853890 (Parts for electrical control/switching apparatus)
Channels 32 isolated digital input channels
Signal Input/Output Types Optically isolated digital inputs; nominal 24 VDC, typically 5–30 VDC compatible; supports active‑low/active‑high logic depending on wiring
Communication Interfaces Via SCXI backplane to NI DAQ (PCI/PXI/USB) through compatible SCXI chassis
Power Requirements Powered by the SCXI chassis backplane; no external supply required for the module itself
Installation Method Single-slot SCXI plug‑in module; field wiring via matching SCXI screw‑terminal blocks and shielded cables
Operating Temperature Typically 0 to 50 °C (indoor control cabinet use)
Dimensions & Weight Standard SCXI single‑slot form factor
Isolation Per‑channel optical isolation (for noise and ground‑loop mitigation)

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

NI SCXI-1163R – 32‑Channel Isolated Digital Input Module for 24 V Industrial SignalsSCXI-1163R

The NI SCXI-1163R is a 32‑channel, optically isolated digital input module designed for SCXI systems. From my experience, it’s the piece you add when you need clean, reliable 24 V (typical 5–30 VDC) digital sensing from the plant floor into your NI DAQ setup—limit switches, proximity sensors, pushbuttons, and dry-contact signals. One thing I appreciate is the isolation; it usually keeps ground loops and electrical noise from creeping into the measurement backplane.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • 32 optically isolated digital inputs – Each channel is isolated to help protect the DAQ system and reduce noise coupling.
  • Industrial voltage compatibility – Works with typical 24 VDC field signals; many setups use 5–30 VDC ranges.
  • Active-low/active-high flexibility – The “R” variant is commonly chosen when reversed or active‑low logic is preferred in the control scheme.
  • SCXI backplane integration – Data is routed through the SCXI chassis to your NI DAQ device for streamlined wiring and system expansion.
  • Field-wiring friendly – Pairs with SCXI screw-terminal accessories for neat, maintainable installations.
  • Channel density – 32 channels in a single SCXI slot helps consolidate cabinets and simplify panel layouts.

Technical Specifications

Brand / Model NI (National Instruments) / SCXI-1163R
HS Code 853890 (Parts for electrical control/switching apparatus)
Channels 32 isolated digital input channels
Signal Input/Output Types Optically isolated digital inputs; nominal 24 VDC, typically 5–30 VDC compatible; supports active‑low/active‑high logic depending on wiring
Communication Interfaces Via SCXI backplane to NI DAQ (PCI/PXI/USB) through compatible SCXI chassis
Power Requirements Powered by the SCXI chassis backplane; no external supply required for the module itself
Installation Method Single-slot SCXI plug‑in module; field wiring via matching SCXI screw‑terminal blocks and shielded cables
Operating Temperature Typically 0 to 50 °C (indoor control cabinet use)
Dimensions & Weight Standard SCXI single‑slot form factor
Isolation Per‑channel optical isolation (for noise and ground‑loop mitigation)

Application Fields

  • Factory automation: reading 24 VDC sensors (limit/prox, photoeyes), E‑stop loops (monitoring only), and machine status lines.
  • Process skids: capturing valve open/close indications, pump run signals, and panel switch positions.
  • Test stands: discrete interlock monitoring and fixture presence detection integrated into NI DAQ systems.
  • Utilities and facilities: door contacts, flow/level switch states, and alarm summaries into SCADA/DAQ.

You might notice that the module fits neatly when teams already have PCI or PXI DAQ cards; the SCXI chassis becomes the clean front-end for field wiring. A maintenance supervisor told us they swapped several DIN rail input blocks for a single SCXI‑1163R and cut troubleshooting time because everything terminated at one labeled terminal block.

Advantages & Value

  • Reliability – Optical isolation and robust SCXI construction tend to handle industrial noise better than standard PC I/O.
  • Compatibility – Integrates with NI DAQ software stacks (LabVIEW, DAQmx) and typical 24 VDC controls hardware.
  • Cost efficiency – 32 channels per slot usually means fewer chassis slots and fewer cables, which lowers panel and labor costs.
  • Scalability – Add more SCXI modules as your I/O grows without redesigning the whole cabinet.
  • Support – We provide pre‑shipment testing and configuration guidance, which seems to reduce commissioning hiccups.

Installation & Maintenance

  • Cabinet & environment – Install in a grounded control cabinet; keep ambient within 0–50 °C and allow frontal ventilation for the SCXI chassis.
  • Wiring – Use shielded cables to the SCXI terminal block; separate high‑voltage or motor drives from signal wiring. Confirm sensor type (PNP/NPN) and wire for the desired active‑low/active‑high behavior.
  • Power & grounding – Power is from the SCXI backplane; maintain a single‑point ground reference and check cabinet earth continuity.
  • Safety – De‑energize field circuits before servicing. The inputs are for signal sensing; do not use as safety‑rated control outputs.
  • Routine maintenance – Quarterly dust removal with dry air; re‑tighten terminal screws; verify channel function via a quick DI loopback test. Keep NI driver/firmware up to date where applicable.

Quality & Certifications

  • Typical conformity: CE and RoHS for electronic modules of this class; many SCXI modules also follow UL safety guidelines.
  • Manufacturer quality systems generally align with ISO standards used in instrumentation manufacturing.
  • Warranty: 365 days replacement/repair policy as noted above.

Recommended Supporting Components

  • SCXI chassis (e.g., SCXI‑1000/SCXI‑1001) and appropriate power supply
  • NI DAQ device with SCXI support (PCI, PXI, or USB interface) and matching cable