Description
NI SCXI-1313A Terminal Block – Screw‑Terminal Connectivity for NI SCXI Measurement Modules
The NI SCXI-1313A is a front‑mount terminal block for the SCXI platform, designed to bring field wiring cleanly and reliably onto your NI SCXI analog input modules. From my experience, the 1313A is the kind of hardware you install once and forget: stable connections, clear labeling, and a form factor that fits neatly on the module face without fighting for panel space. You might notice that it keeps wiring straightforward for multi-channel applications—exactly what you want in maintenance-heavy test racks or long-running monitoring setups.
Typical use cases include multi-point temperature or voltage logging on SCXI analog input modules, retrofitting legacy benches where screw-terminal access is a must, and quick sensor swaps during troubleshooting. One thing I appreciate is how it shortens the “last inch” between sensor leads and the SCXI module, which in many cases helps reduce noise pickup compared to flying leads or improvised adapters.
Our Order Placement Process and Guarantees
- Warranty: 365 days
- Lead time: 1 week if in stock; no more than 1 month at the latest
- Payment: 50% advance payment; full payment before delivery
- Express delivery: FedEx, UPS, DHL
- Each unit is function-checked before dispatch and packaged for safe transit
Key Features
- Direct front‑mount design – Attaches to the face of the compatible SCXI module, minimizing wiring distance and simplifying panel layout.
- Screw‑terminal connectivity – Tool-friendly terminals for dependable field wiring; ideal for frequent sensor changes and service work.
- Clear channel labeling – Channel marks and reference points help reduce wiring mistakes during installation or rework.
- Low‑noise routing – Short internal paths to the module input reduce the chance of pickup compared with longer fly leads.
- SCXI system fit – Works within the established SCXI chassis/module ecosystem, which is still widely used in legacy test stands.
- Passive, no external power – Nothing to configure or power; once mounted and tightened, it’s ready to use.
Technical Specifications
| Brand / Model | National Instruments (NI) / SCXI-1313A |
| Product Type | Front‑mount screw‑terminal block for NI SCXI modules (passive) |
| HS Code | 853690 (Electrical apparatus for making connections to or in electrical circuits) |
| Power Requirements | None (passive terminal block, powered by associated SCXI module if needed for detection) |
| Signal Input/Output Types | Field wiring via screw terminals routed to SCXI analog inputs; suitable for thermocouples, voltage, or other low‑level signals depending on the paired module |
| Communication Interfaces | None (no digital/serial interface; mechanical terminal block only) |
| Compatible Systems/Modules | SCXI chassis and compatible NI SCXI analog input modules (commonly used with SCXI‑1100/1102 series; confirm per module manual) |
| Installation Method | Front‑mount to SCXI module; secure with captive screws; route field wires through panel cutout as required |
| Operating Environment | Follows SCXI chassis/module environmental ratings for temperature and humidity |
Related or Supporting Products
- NI SCXI-1300 – General‑purpose screw‑terminal block for SCXI analog input modules; good when you don’t need isothermal or special sensor features.
- NI SCXI-1303 – Isothermal terminal block with cold‑junction reference, typically chosen for thermocouple work with SCXI input modules.
- NI SCXI-1314/1314B – Terminal blocks tailored for strain/bridge measurements (with bridge completion and excitation routing on compatible modules).
- NI SCXI-1102 – 32‑channel thermocouple/low‑voltage input module often paired with isothermal terminal blocks.
- NI SCXI-1100 – Multiplexed analog input module commonly used for general sensor and voltage inputs in SCXI racks.
Quick feedback from a lab maintenance lead: “Swapping sensors on the 1313A took minutes, not hours. The channel labeling saved us a round of rewiring during commissioning.”
Installation & Maintenance
- Mounting – Power down the SCXI chassis. Align the SCXI‑1313A with the module faceplate and tighten the captive screws evenly. Avoid overtightening.
- Cabinet and ventilation – Install the SCXI chassis in a cabinet that respects airflow paths. Keep low‑level signal wiring away from high‑voltage or high‑current lines.
- Wiring practice – Use consistent wire types and lengths per channel group. Maintain good strain relief and shielding practices to minimize noise and ground loops.
- Safety – De‑energize circuits before touching field wiring. Follow sensor/vendor wiring polarity and the SCXI module’s input limits.
- Routine checks – Periodically re‑seat terminal screws, inspect for oxidation or frayed conductors, and verify channel labeling matches your system configuration.
- Firmware/Calibration – The 1313A is passive, but keep the paired SCXI module firmware/drivers current and perform regular system calibration as required by your quality plan.
Quality & Certifications
- Manufacturer quality system typically certified to ISO 9001
- CE conformity for use within the SCXI system context
- RoHS status may vary for legacy SCXI accessories; we supply compliant or vetted stock where available
- 365‑day warranty from us; units are inspected and securely packaged prior to shipment







Reviews
There are no reviews yet.