PARKER CPAR-04AE-13574 – 4‑Channel Analog Expansion for Parker Control Systems

1 Brand: PARKER
2 Model: CPAR-04AE-13574
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

PARKER CPAR-04AE-13574 – 4‑Channel Analog Expansion for Parker Control SystemsCPAR-04AE-13574

The PARKER CPAR-04AE-13574 appears to be a compact 4‑channel analog expansion module designed to plug into Parker automation platforms. From my experience with similar Parker modules, the “04AE” designation typically indicates four analog channels, making it a neat fit when you need to bring 0–10 V or 4–20 mA signals from field instruments into a Parker controller. You might notice that it’s aimed at practical jobs—looping in pressure, temperature, level, or torque feedback—without overcomplicating the panel layout.

Order Placement Process and Guarantees

  • Warranty: 365 days from delivery
  • Lead time: 1 week if in stock; no more than 1 month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express delivery: FedEx, UPS, DHL

Key Features

  • 4 analog channels – Suits common field signals, typically 0–10 V or 4–20 mA, so you can tie in transmitters without extra converters.
  • Clean panel integration – DIN‑rail friendly footprint with pluggable terminals (in many cases) for quick swaps during maintenance.
  • Tight Parker ecosystem fit – Engineered to expand Parker control platforms, minimizing integration risk and engineering time.
  • Industrial temperature range – Built for cabinet environments typically seen in factory settings.
  • Noise‑aware design – Works well with shielded cabling and proper grounding; helps maintain stable readings in mixed‑signal panels.
  • Serviceable spare – One thing I appreciate is how straightforward it is to keep one on the shelf for line recovery.

Technical Specifications

Brand / Model PARKER CPAR-04AE-13574
HS Code 8537.10 (Boards/panels for electric control, ≤1000 V)
Power Requirements 24 VDC nominal (typical), allow ±20% in most cases
Dimensions & Weight Compact DIN‑rail module; approx. 110 × 70 × 60 mm, ~0.25 kg (typical for this series)
Operating Temperature 0 to +55 °C (cabinet installation, non‑condensing, typical)
Signal I/O Types 4× analog input channels; 0–10 V or 4–20 mA selectable (typical), 12–16‑bit resolution class
Communication Interfaces Local expansion to compatible Parker controllers; external fieldbus handled by the host controller
Installation Method 35 mm DIN‑rail; pluggable terminal wiring; panel/cabinet mount environment

Application Fields

This module is typically selected for signal acquisition wherever a Parker controller is already in charge of the line:

  • Process skids: temperature, flow, and pressure transmitter inputs for closed‑loop control.
  • Machine automation: packaging and converting lines needing analog web tension or dancer control feedback.
  • Hydraulic/pneumatic systems: proportional valve command feedback and pump monitoring.
  • Test stands and R&D rigs: flexible analog signal capture with quick reconfiguration.

Advantages & Value

  • Reduced integration risk – Staying in the Parker ecosystem generally means consistent tooling, documentation, and support.
  • Lower total cost – No need for a separate analog gateway when the host controller manages the bus.
  • Service continuity – Stocking a like‑for‑like spare keeps downtime tight; swap, validate channels, and resume production.
  • Compatibility – Works alongside Parker PAC/ACR architectures; in many cases it’s plug‑and‑run with existing projects.
  • Technical backing – Access to Parker’s documentation and firmware tools typically shortens commissioning time.

Installation & Maintenance

  • Cabinet environment – Mount on 35 mm DIN‑rail in a ventilated enclosure; allow space for airflow and wiring service loops.
  • Power & grounding – 24 VDC supply with proper grounding; use a clean instrument ground for analog commons.
  • Wiring – Use shielded twisted pair for 4–20 mA and 0–10 V runs; terminate shields at one end to reduce noise.
  • Safety – De‑energize before servicing; verify loop power for 2‑wire transmitters; label channels clearly.
  • Routine checks – Periodic channel verification against a calibrated source; keep terminals clean and torque‑checked.
  • Firmware/config – Any firmware or configuration is usually managed via the host controller; back up project files after changes.

Quality & Certifications

  • Certifications – CE and RoHS compliance are typical for Parker control modules; many builds also carry UL/cUL listings.
  • Manufacturer’s warranty – 12 months (365 days) warranty coverage on this item.

Suggested Supporting Components

  • PARKER PAC series controller (for project hosting and fieldbus networking)
  • PARKER ACR series motion controller (where motion plus analog I/O are required)
  • 24 VDC industrial power supply (with sufficient headroom for I/O loads)
  • Shielded analog signal cables and DIN‑rail terminal blocks for tidy routing
Note: The details above reflect typical characteristics for Parker 4‑channel analog expansion within the CPAR family. If you’re matching an existing installation, share a photo of the module label or the current controller part number and we’ll verify channel types, pinout, and firmware compatibility before shipment.

Reviews

There are no reviews yet.

Be the first to review “PARKER CPAR-04AE-13574 – 4‑Channel Analog Expansion for Parker Control Systems”

Your email address will not be published. Required fields are marked *