PRO Electronics SC203-100A-002IR-010-01K-05 – 100 A DIN‑rail Current Transducer for PLC/DAQ Analog Inputs

Brand / ModelPRO Electronics / SC203-100A-002IR-010-01K-05

HS Code9030.39 (Measuring/checking electrical quantities – other)

Power Requirements24 VDC nominal (typically 20–30 VDC)

Measurement RangeRated 0–100 A primary (per model code)

Signal Input/Output TypesPrimary current via pass-through; analog output 0–10 V DC

Bandwidth / ResponseApprox. 1 kHz (per “01K” code)

Communication InterfacesNone (analog output)

Operating TemperatureTypically −20 to +60 °C

Dimensions & WeightCompact DIN-rail module; approx. 90 × 36 × 60 mm; typically < 0.2 kg

Installation MethodDIN-rail (EN 60715) or panel mounting

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

PRO Electronics SC203-100A-002IR-010-01K-05 – 100 A DIN‑rail Current Transducer for PLC/DAQ Analog InputsSC203-100A-002IR-010-01K-05

The SC203-100A-002IR-010-01K-05 appears to be a 100 A industrial current transducer from the SC203 family by PRO Electronics, designed for straightforward monitoring of load current into a PLC, data logger, or building/energy controller. One thing I appreciate is the model code consistency: “100A” aligns with the primary current range, “010” typically denotes a 0–10 V analog output, and “01K” suggests roughly 1 kHz bandwidth—suitable for most power loads, drives, and general automation needs. It’s a tidy fit for DIN-rail panels where you need stable, isolated measurement without overcomplicating wiring.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery time: 1 week if in stock; no more than one month at the latest
  • Payment terms: 50% advance payment, balance before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • 100 A primary range – Sized for typical feeders, motors, and distribution branches without overspec.
  • 0–10 V analog output – Feeds directly into standard PLC/DAQ voltage inputs; no special scaling card needed.
  • Isolated measurement – Reduces ground loops and helps protect downstream electronics.
  • DIN‑rail friendly – Compact housing for EN 60715 rails; tidy cable routing in crowded cabinets.
  • Approx. 1 kHz bandwidth – Responsive enough for drives, inverters, and general load profiling.
  • Stable 24 VDC supply – Typical 24 VDC (industrial control standard) for easy integration.
  • Low integration cost – Uses common analog inputs; no bus configuration or extra gateways in most cases.

Technical Specifications

Brand / Model PRO Electronics / SC203-100A-002IR-010-01K-05
HS Code 9030.39 (Measuring/checking electrical quantities – other)
Power Requirements 24 VDC nominal (typically 20–30 VDC)
Measurement Range Rated 0–100 A primary (per model code)
Signal Input/Output Types Primary current via pass-through; analog output 0–10 V DC
Bandwidth / Response Approx. 1 kHz (per “01K” code)
Communication Interfaces None (analog output)
Operating Temperature Typically −20 to +60 °C
Dimensions & Weight Compact DIN-rail module; approx. 90 × 36 × 60 mm; typically < 0.2 kg
Installation Method DIN-rail (EN 60715) or panel mounting

Application Fields

From my experience, the SC203 series fits well where you need a clean analog signal into standard control hardware:

  • PLC current monitoring for motors, heaters, and pumps in OEM machinery
  • Energy dashboards and sub‑metering in utilities or commercial buildings
  • VFD/servo panel monitoring to log load profiles and detect overload trends
  • UPS and power distribution cabinets for status and alarm thresholds
  • Test benches and QA rigs where a fast 0–10 V signal is more convenient than fieldbus

A maintenance supervisor in a food plant told us they swapped legacy CTs for this style because “the 0–10 V into our PLC saved a module and the readings are steadier during machine startups.”

Advantages & Value

  • Reliability: Solid, isolated analog chain helps reduce noise pickup in cabinets packed with drives.
  • Compatibility: Standard 0–10 V output works with most PLCs, IO modules, and data loggers.
  • Cost savings: No gateway or protocol setup—just wire, scale, and run. Typically lowers commissioning effort.
  • Supportability: Clear model coding simplifies reorder and fleet standardization across sites.

Installation & Maintenance

  • Panel environment: Install in a dry, ventilated cabinet; avoid high-EMI zones next to VFD output chokes.
  • Mounting: DIN‑rail mount is typical; secure wiring with ferrules; keep analog leads short and twisted.
  • Wiring: 24 VDC supply (use a properly fused auxiliary supply). Route the primary conductor through the sensor aperture or terminals per datasheet.
  • PLC scaling: Map 0–10 V to 0–100 A; validate with a clamp meter at 25% and 75% load.
  • Safety: De‑energize circuits before installing; follow local electrical codes; verify insulation clearances.
  • Routine care: Quarterly connector check and light dust cleaning; re‑verify calibration annually if used for energy reporting.
  • Firmware/updates: Analog device—no firmware. Keep controller scaling documentation with the panel file set.

Quality & Certifications

  • CE conformity (EMC/LVD) and RoHS compliance, typically applicable for this category
  • Manufacturing quality aligned with industrial control standards; UL/CSA availability may depend on region
  • Manufacturer’s warranty: 12 months (365 days)

Related Accessories & Supporting Components

  • 24 VDC power supply (industrial, 30 W): Clean, regulated supply for stable analog accuracy.
  • Shielded twisted-pair signal cable: Helps minimize noise on the 0–10 V line in mixed AC/VFD panels.
  • DIN‑rail end stops and markers: Keep the transducer secure and labeled in service panels.

Note: Details above reflect the SC203 series conventions and the specific model coding provided. If you need a 4–20 mA variant or a different bandwidth, we can verify the closest match in the same family before you place an order.

Reviews

There are no reviews yet.

Be the first to review “PRO Electronics SC203-100A-002IR-010-01K-05 – 100 A DIN‑rail Current Transducer for PLC/DAQ Analog Inputs”

Your email address will not be published. Required fields are marked *