Schneider Electric 140ACI03000 – Modicon Quantum Analog Current Input Module for Process Signals

Brand / Model Schneider Electric 140ACI03000
System Family Modicon Quantum – Analog Current Input Module
HS Code 8538.90 – Parts for electrical control equipment (final classification may vary by country)
Power Requirements Supplied via Quantum backplane (no separate external power on the module)
Signal Input Types Analog current inputs, typically 0…20 mA and 4…20 mA (channel‑configurable)
Communication Interface Modicon Quantum backplane to CPU (local rack)
Installation Method Quantum single‑slot plug‑in; front removable terminal block for field wiring
Operating Temperature Typically 0…+60 °C (cabinet‑installed; non‑condensing)
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Schneider Electric 140ACI03000 – Modicon Quantum Analog Current Input Module for Process Signals

The Schneider Electric 140ACI03000 is an analog current input module for the Modicon Quantum platform. From my experience, plants use this card to bring 0/4–20 mA transmitters into a Quantum rack—flow, level, pressure, or position feedback where stability and diagnostics beat fancy extras. You might notice the standard Quantum front connector and clear labeling, which typically makes commissioning and swap‑outs straightforward during short maintenance windows.

Schneider Electric 140ACI03000 Modicon Quantum analog current input module

Company’s Order Placement Process and Guarantees

  • Warranty period: 365 days
  • Delivery time: 1 week for in-stock; no more than one month at the latest
  • Payment method: 50% advance payment, full payment for delivery
  • Express delivery: FedEx, UPS, DHL
  • Pre‑shipment: functional/visual check and ESD‑safe, shock‑resistant packing

Key Features

  • Analog current inputs – Accepts standard transmitter signals (typically 0…20 mA and 4…20 mA) used across process plants.
  • Quantum rack integration – Direct backplane connection for fast data exchange with the CPU and clear diagnostics.
  • Channel configuration – Ranges and filters are configured in the Quantum project, which keeps mixed loops tidy.
  • Noise‑tolerant design – Industrial‑grade input circuitry for stable readings over long cable runs, in most cases without extra hardware.
  • Service‑friendly front end – Removable terminal block and clear labeling simplify commissioning and troubleshooting.

Technical Specifications

Brand / Model Schneider Electric 140ACI03000
System Family Modicon Quantum – Analog Current Input Module
HS Code 8538.90 – Parts for electrical control equipment (final classification may vary by country)
Power Requirements Supplied via Quantum backplane (no separate external power on the module)
Signal Input Types Analog current inputs, typically 0…20 mA and 4…20 mA (channel‑configurable)
Communication Interface Modicon Quantum backplane to CPU (local rack)
Installation Method Quantum single‑slot plug‑in; front removable terminal block for field wiring
Operating Temperature Typically 0…+60 °C (cabinet‑installed; non‑condensing)

Application Fields

The 140ACI03000 shows up anywhere a Quantum rack needs clean analog current signals:

  • Water & wastewater – 4–20 mA pressure, level, and flow transmitters across distributed panels.
  • Chemicals & refining – setpoint and feedback loops where noise immunity matters.
  • Power & utilities – boiler/BOP instrumentation integrated into Quantum DCS islands.
  • Food & beverage – CIP/skid controls using standardized 4–20 mA devices.

One thing I appreciate is how predictable the swap is. A maintenance engineer told me, “We moved the terminal block over, validated ranges in the project, and readings came in steady within minutes.”

Advantages & Value

  • Reliability – Stable inputs for 24/7 loops; fewer nuisance trips when shielding is done right.
  • Compatibility – Native to Modicon Quantum racks; preserves existing wiring and PLC logic.
  • Cost control – Keeps installed Quantum systems productive; avoids premature platform migration.
  • Support – We can help confirm terminal style, channel ranges, and project parameters before you shut down.

Installation & Maintenance

  • Panel standards: Install in a clean, ventilated cabinet; maintain ambient typically 0…60 °C; non‑condensing humidity.
  • Wiring: Use twisted, shielded pairs for 4–20 mA; bond shields at the panel; separate from VFD motor leads.
  • Commissioning: Configure ranges and filtering in the Quantum project; verify scaling against a loop calibrator.
  • ESD & handling: Use a grounded strap; handle by edges; seat firmly to ensure full backplane engagement.
  • Routine care: Periodic terminal re‑torque, dust cleaning, and a quick input noise check during planned stops.

Quality & Certifications

  • Manufactured under Schneider Electric quality systems (ISO 9001 aligned).
  • CE marking for EMC/safety; many Quantum modules are UL/cUL Recognized for industrial control.
  • RoHS compliance by series generation; confirmable by part/serial if needed.
  • Warranty: 365 days repair/replace coverage from delivery.

Reviews

There are no reviews yet.

Be the first to review “Schneider Electric 140ACI03000 – Modicon Quantum Analog Current Input Module for Process Signals”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products