Description
Schneider Electric ASSY-12149 – OEM Replacement Assembly for Industrial Control Systems
The Schneider Electric ASSY-12149 is an original OEM assembly typically used as a board-level replacement inside Schneider-controlled machines and panels. From my experience, this kind of spare part is the quickest way to get a downed line back into production without re-engineering the whole control cabinet. You might notice that lead times for complete modules can fluctuate, while a direct assembly swap often restores functionality in one service window.
One thing I appreciate is how these assemblies are designed to slot into the existing host unit/backplane, so wiring stays mostly intact and compatibility is predictable. It seems to be the preferred approach for maintenance teams who want minimal downtime and a parts trail that matches Schneider’s documentation.
Our Order Process & Guarantees
- Warranty: 365 days from delivery
- Delivery: 1 week when in stock; no more than 1 month latest
- Payment: 50% advance; balance before dispatch
- Express options: FedEx, UPS, DHL
- Pre-shipment functional check and protective packaging for ESD-sensitive parts
Key Features
- Genuine Schneider OEM assembly – Ensures form-fit-function alignment with the original design.
- Board-level replacement – Installs inside the host module; no cabinet redesign required in most cases.
- Backplane-powered – Typically draws 24 VDC from the host unit’s internal power, simplifying field wiring.
- Controlled compatibility – Works within the intended Schneider platform, helping avoid firmware or parameter surprises.
- Service-friendly – ESD-protected packaging and straightforward mounting points for quick swap-outs.
Technical Specifications
| Brand / Model | Schneider Electric / ASSY-12149 |
| HS Code | 853890 (Parts suitable for use with industrial control apparatus) |
| Power Requirements | Nominal 24 VDC supplied via host/backplane (consumption depends on platform) |
| Operating Temperature | 0 to +55 °C when installed in a ventilated control cabinet (typical) |
| Signal I/O | No direct field I/O; interfaces internally through the host module’s connectors |
| Communication Interfaces | Internal system bus / board-to-board connectors (no external ports on the assembly) |
| Installation Method | Board-level replacement; secure with screws/standoffs per Schneider service manual; ESD handling required |
Application Fields
While the exact host platform can vary, assemblies like ASSY-12149 are commonly found in:
- Packaging and converting lines (cartoners, wrappers, labelers)
- Material handling systems (conveyors, sorters, palletizing cells)
- F&B and pharma equipment with strict uptime expectations
- Light assembly and machine tools using Schneider control platforms
A maintenance lead at a beverage plant told us they swapped an ASSY-series board in under 30 minutes and brought the filler back online without touching any field wiring—exactly the kind of downtime win most teams aim for.
Advantages & Value for Procurement
- Reliability: Genuine Schneider parts typically maintain original MTBF and thermal performance.
- Compatibility: Form-fit-function alignment reduces the risk of firmware or parameter mismatches.
- Cost Control: Replace only what’s failed—often less expensive than purchasing a complete module.
- Traceability: OEM labeling and batch trace support your quality and audit processes.
- Support: Access to installation guidance and post-sales follow-up if something doesn’t behave as expected.
Installation & Maintenance
- Environment: Install in a clean, dry, ventilated control cabinet; avoid corrosive gases and excessive vibration.
- Power & Wiring: Isolate all power (24 VDC and mains) before service. Photograph and label connectors before removal.
- ESD Safety: Use a grounded wrist strap and ESD mat. Handle by edges; never touch component leads.
- Mounting: Seat the board evenly into the host; tighten screws to the torque recommended in Schneider’s service documentation.
- Commissioning: After installation, perform a visual check, restore power, and run a functional test at low load first.
- Routine Care: Keep filters clean, check for loose connectors during scheduled stops, and back up configurations. Firmware changes should follow the host platform’s release notes.
Quality & Certifications
- Manufactured under ISO 9001 quality systems
- RoHS-compliant materials and processes (typical for Schneider assemblies)
- Designed for use within CE/UL-certified Schneider systems when installed as intended
- Warranty: 365 days
Common Supporting Components (for reference)
To keep spares aligned with your installed base, teams often stock a few companion items. These are typical in Schneider-powered cabinets—please confirm against your BOM before ordering:
- ABL8RPS24030 / ABL8RPS24100 – 24 VDC Phaseo power supplies (3 A / 10 A) used to power control electronics.
- NSYAM Series DIN rails – For clean mounting and grounding in the control cabinet.
- ESD Service Kit – Wrist strap, mat, and antistatic bags to protect sensitive assemblies during handling.
Need us to cross-check ASSY-12149 against your exact controller or HMI model? Share the host unit number and a photo of the nameplate, and we’ll verify fit and any revision notes before you place the order.







Reviews
There are no reviews yet.