Description
TRICONEX 3006 – 6‑Slot Chassis for Tricon TMR Safety Systems
The TRICONEX 3006 is a compact 6‑slot chassis designed for Tricon triple modular redundant (TMR) safety instrumented systems. From my experience, this frame is chosen when panel space is tight or when a small, independent safety node is needed near the process. You might notice that it follows the familiar Tricon backplane architecture, so it accepts standard Triconex processor and I/O modules, supports hot‑swap practices, and maintains the deterministic triplicated backplane signaling that SIS engineers expect.
Typical use cases include localized ESD/SIS islands, brownfield expansions where only a handful of I/O are required, or segregated applications (e.g., burner management or compressor protection) where a smaller, self‑contained Tricon node saves cabinet space and wiring runs. One thing I appreciate is how it keeps the installation straightforward: standard 19‑inch rack mounting, clean module guides, and proper grounding paths for low‑noise operation.
Order Placement Process and Guarantees
- Warranty: 365 days
- Lead time: 1 week if in stock; no more than 1 month latest
- Payment: 50% advance payment, full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- 6‑slot Tricon backplane – Compact footprint that fits where space is limited while keeping full TMR integrity.
- TMR signal architecture – Triplicated buses and voting paths for high availability and deterministic safety behavior.
- Hot‑swap module handling – Supports insertion/removal of compatible Triconex modules under power in most cases to reduce downtime.
- Redundant power feed design – Accommodates dual power inputs via system power modules for higher resilience.
- Clean grounding and shielding – Backplane and chassis bonding points to help minimize electrical noise in industrial cabinets.
- Straightforward installation – 19‑inch rack mounting with front‑insertion module guides for quick assembly and service.
- Broad module compatibility – Works with standard Triconex processors (e.g., 35xx series) and 36xx/37xx I/O families.
Technical Specifications
| Brand / Model | TRICONEX 3006 |
| HS Code | 8538.90 (Parts for apparatus of heading 8537) |
| Power Requirements | 24 VDC nominal to the Tricon power bus (typically via redundant system power modules) |
| Form Factor | 19‑inch rack; compact 6‑slot Tricon chassis (front‑insertion modules) |
| Operating Temperature | 0 to 60°C (typical industrial environment) |
| Signal Backplane | Triplicated TMR backplane for CPU/I&O voting, diagnostics, and scan synchronization |
| Communication Interfaces | Provided by installed processor/communication modules (e.g., Ethernet, serial, Modbus) via backplane |
| Installation Method | Rack mounting inside a control cabinet; dedicated grounding; front service access |
Application Fields
The 3006 is suitable for safety‑critical nodes where a small Tricon footprint is preferred:
- Oil & Gas – ESD skids, wellhead protection, compressor or pipeline station safety
- Petrochemical & Refining – Burner management, flare systems, local interlocks
- Power Generation – Turbine/boiler protection subsystems and BOP safety logic
- Chemicals & Pulp/Paper – Localized SIS cells near process units to shorten wiring
- Mining & Metals – Machine safety interlocks and emergency shutdown nodes
Advantages & Value
- Reliable, recognized platform – Tricon TMR is widely deployed and, in many cases, preferred by safety engineers.
- Compatibility – Works with established Triconex processors (35xx series) and 36xx/37xx I/O modules, easing spares management.
- Lifecycle pragmatism – Smaller chassis means lower cabinet space, lower wiring, and typically faster field installation.
- Serviceability – Hot‑swap support and front access reduce maintenance time compared with non‑modular designs.
- Procurement flexibility – Used both for new SIS nodes and as drop‑in hardware in brownfield expansions.
A refinery maintenance lead told me they chose the 3006 for a remote burner management upgrade—“it was the only way to fit a full TMR set with enough I/O into the existing cabinet without a rebuild.”
Installation & Maintenance
- Cabinet & mounting – Install in a clean, dry 19‑inch control cabinet with adequate ventilation; avoid heat sources and high‑EMI areas.
- Power & grounding – Provide clean 24 VDC via redundant power modules where possible; bond the chassis to cabinet earth at designated points.
- Wiring practices – Segregate low‑level signals from power cables; maintain bend radii and use shield terminations as per site standards.
- Safety & ESD – De‑energize affected segments when practical; use ESD protection during module insertion/removal.
- Routine checks – Visually inspect connectors and backplane, clean dust with dry air, verify power redundancy, and review diagnostics during planned outages.
- Firmware & calibration – Firmware updates and calibrations apply to processor/I/O modules; the chassis itself typically requires minimal maintenance.
Quality & Certifications
- Triconex systems are assessed for IEC 61508 SIL3 applications (system‑level, with certified processors/I&O)
- Products typically carry CE marking; UL and RoHS compliance may apply depending on exact configuration
- Manufacturer quality programs align with ISO‑based processes for industrial controls
- Warranty: 365 days (as per order terms listed above)
Notes: The TRICONEX 3006 is a chassis/backplane assembly; communication, processing performance, and I/O capabilities depend on the specific processor and I/O modules installed. If you’re matching an existing site standard, share the installed module list (e.g., 35xx CPU, 36xx/37xx I/O) and expected power budget so we can double‑check slot usage and redundancy settings.


Reviews
There are no reviews yet.