Description
VIBRO-METER EA402 (913-402-000-012) — Industrial signal conditioner for vibration and dynamic process monitoring
The VIBRO-METER EA402 is a compact conditioning module used to power and condition piezoelectric vibration sensors and route clean, scaled signals to control or protection systems. The build code 913-402-000-012 indicates a specific factory configuration of the EA402, typically preset for IEPE-type accelerometers with a proportional process output (commonly 4–20 mA) and a buffered dynamic output for diagnostics. From my experience, it’s a practical fit when you need dependable vibration trending into a DCS/PLC while keeping a full-bandwidth signal available for deeper analysis.
Our Order Placement Process and Guarantees
- Warranty: 365 days coverage
- Lead time: 1 week when in stock; no more than 1 month at the latest
- Payment terms: 50% advance payment; full payment before delivery
- Express delivery: FedEx, UPS, DHL
- Traceability: we confirm the full part code 913-402-000-012 before shipping to match your installed base
Key Features
- IEPE sensor excitation — Provides constant-current power for piezoelectric accelerometers; simplifies field wiring and improves noise immunity.
- 4–20 mA proportional output — Sends a scaled RMS or peak value to DCS/PLC for trending and thresholds, typically configurable to match your engineering units.
- Buffered dynamic output — Preserves the full AC waveform for diagnostics or route-based analysis; handy for portable analyzers during outages or startups.
- Filtering and scaling — High-pass/low-pass filtering and gain options (factory set by build code) reduce low-frequency drift or unwanted bands.
- Industrial 24 VDC power — Typically powered from a 24 VDC cabinet supply for easy integration and redundancy schemes.
- Robust, cabinet-ready design — Designed for continuous use in machinery protection and condition monitoring environments.
“We paired an EA402 with two IEPE accelerometers on a critical pump. The plant kept a 4–20 mA feed into the DCS while maintenance plugged into the buffered output for FFT checks. Installation was fast and the noise floor seemed lower than the old conditioner.”
Technical Specifications
| Brand / Model | VIBRO-METER EA402 (Part code: 913-402-000-012) |
| HS Code | 9031.80 (Measuring/monitoring instruments, vibration/condition monitoring equipment) |
| Power Requirements | 24 VDC nominal (18–32 VDC typical) |
| Signal Input / Output | IEPE accelerometer input with constant-current excitation; 4–20 mA process output; buffered AC dynamic output |
| Communication Interfaces | Analog outputs (no fieldbus); relay/alarm contacts available on some configurations |
| Operating Temperature | –20 to +70 °C (industrial range, typical) |
| Installation Method | Cabinet-mounted module; typically DIN-rail or panel mount depending on build |
| Dimensions & Weight | Compact module format; exact outline drawing supplied per 913-402-000-012 build |
Related or Supporting Products
- VIBRO-METER TQ402 (charge amplifier) — For charge-output accelerometers in high-temperature applications; pairs when IEPE is not feasible.
- VIBRO-METER VM600 Mk2 — Rack-based protection and condition monitoring; the EA402’s 4–20 mA can be paralleled to DCS while VM600 handles trip logic and advanced analytics.
- IEPE industrial accelerometers — Standard 100 mV/g or 500 mV/g types for pumps, fans, and gearboxes; select ranges to match the EA402 scaling.
- Phoenix Contact QUINT4-PS/1AC/24DC/5 — Stable 24 VDC DIN-rail power supply; good choice for redundant EA402 power rails.
- Shielded sensor cabling (e.g., Belden low-noise coax) — Reduces triboelectric noise for the buffered dynamic output; keep runs short where possible.
Installation & Maintenance
- Cabinet & environment — Mount in a ventilated control cabinet (IEC 61439 practices). Keep away from high-EMI sources and VFD cabling; maintain ambient within the specified industrial range.
- Wiring — Use shielded cable for IEPE inputs and the buffered output. Ground shields at one end only to avoid loops. Separate low-level sensor leads from power lines.
- Power — Feed from a clean 24 VDC supply; in many cases a dedicated, fused rail with surge protection improves long-term stability.
- Configuration — Confirm the scaling (engineering units), filter cutoffs, and alarm thresholds match your machine. The 913-402-000-012 build is typically factory-set; we can verify against your datasheet.
- Routine checks — Quarterly sensor bias checks and a functional bump test help spot wiring or sensor issues. Re-verify loop scaling annually; clean terminals and re-torque connections.
- Serviceability — Buffered output lets you plug in a portable analyzer without disturbing the control loop, which saves time during outages.
Quality & Certifications
- CE marking for industrial EMC and safety (typical for EA-series modules)
- RoHS compliance
- Manufactured under ISO 9001 quality management
- Manufacturer’s standard warranty practices apply; we provide 365-day warranty coverage on supply
You might notice that plants standardizing on EA402 appreciate the simple recipe: IEPE in, 4–20 mA out, waveform always available. If you’re matching a legacy installation, share a photo of the module label and your sensor type — we’ll confirm compatibility with 913-402-000-012 and have it on the way by express.







Reviews