Description
Vibro‑Meter (Meggitt) VM600 MPC4SIL – Safety‑rated machine protection card for critical rotating equipment
The VM600 MPC4SIL is the safety‑rated machine protection card used in Vibro‑Meter’s VM600 rack. It’s built for high‑integrity shutdown and alarm functions on turbines, compressors, generators, and other high‑value rotating assets where proven SIL compliance is expected. In most cases, the MPC4SIL pairs with an IOC4TSIL rear I/O card to form a 4‑channel protection slice with voting logic, redundant relays, and tight integration to the rack CPU for plant communications. From my experience, it’s a go‑to choice when users want API 670‑style protection behavior with a clear SIL safety case.
Our Order Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- SIL‑rated protection slice – The MPC4SIL with IOC4TSIL delivers safety‑integrity machine protection, typically applied where a SIL 2 loop is required under IEC 61508/61511.
- Four dynamic measurement channels – Designed to work with vibration and position inputs (e.g., accelerometers, velocity sensors, eddy‑current proximity probes) for shutdown and alarms.
- Overspeed/Keyphasor support – Works with tachometer/Keyphasor inputs for speed‑related logic and alarm tracking in turbomachinery applications.
- Redundant relay outputs – Safety relays on the rear I/O provide latched trip and alarm contacts with voting options for robust shutdown circuits.
- API 670‑style alarming – You get familiar alarm types (alert/danger), time delays, latching behavior, and channel logic that maintenance teams expect.
- Rack‑level integration – Communicates via the VM600 backplane with the CPU/Ethernet module for system diagnostics, configuration, and plant connectivity.
- Continuous self‑diagnostics – Built‑in monitoring of channel health, relay paths, and configuration integrity helps reduce spurious trips.
- Field‑proven ecosystem – Compatible with a wide range of Vibro‑Meter sensors and transducers, which simplifies brownfield upgrades.
One thing I appreciate is how predictable the setup feels if you’ve worked with VM600 before—the SIL version doesn’t complicate day‑to‑day workflows, yet it tightens the safety story. A maintenance lead at a gas compressor station told us the proof‑test routine “took less than an hour per train” once their procedure was dialed in.
Technical Specifications
| Brand / Model | Vibro‑Meter (Meggitt) VM600 MPC4SIL |
| HS Code | 9032.89 (Automatic regulating or controlling instruments; other) |
| Power Requirements | Powered via VM600 rack backplane; rack supply typically 24 VDC via VM600 power module (e.g., RPS6U) |
| Dimensions & Weight | 6U VM600 plug‑in front card; pairs with IOC4TSIL rear I/O. Eurocard format; typical depth around 220 mm; weight under 1 kg (module only). |
| Operating Temperature | 0 to +55 °C (typical for VM600 rack modules) |
| Signal I/O Types | Up to 4 dynamic channels via IOC4TSIL for vibration/position sensors; Keyphasor/speed inputs; buffered outputs and safety relays on rear I/O |
| Communication Interfaces | Via VM600 CPU/Ethernet module (e.g., CPUM) over backplane; supports plant protocols such as Modbus/TCP and access via Vibro‑Meter software |
| Installation Method | Front card plugs into VM600 19‑inch rack; matched with IOC4TSIL rear card. DIN‑style backplane connectors; guided insertion/extraction. |
| Safety Integrity | SIL‑rated (commonly applied for SIL 2 loops) under IEC 61508/61511, when used as a pair with the proper rear I/O and per the validated proof‑test interval |
Related and Supporting Products
- IOC4TSIL – Rear I/O card that pairs with MPC4SIL; provides sensor terminations, buffered outputs, and safety relays.
- VM600 Rack & Backplane – 19‑inch, 6U chassis hosting protection and monitoring slices.
- CPUM (VM600 CPU/Ethernet) – System controller for configuration, data access, and Modbus/TCP communications.
- RPS6U Power Supply – Provides the 24 VDC rack supply and power redundancy options.
- VM600 MPC4 (standard) – Non‑SIL version used where functional safety certification isn’t required; functionally similar for non‑safety applications.
- VM600 Mk2 / VM600S platform – Newer generation hardware with extended cybersecurity and lifecycle support; suitable for brownfield upgrades when planning long‑term fleet standardization.
- Vibro‑Meter proximity and vibration sensors – For example, eddy‑current probes (proximitor systems) and piezoelectric accelerometers commonly used with IOC4TSIL.
Installation & Maintenance
- Panel and rack – Mount in a clean, ventilated 19‑inch cabinet. Maintain clearance for airflow and front access to indicators and extraction levers.
- Wiring – Use shielded, twisted pairs for sensor runs. Ground shields at the rack end (typical practice) to limit ground loops. Separate relay and signal wiring.
- Pairing – Always match MPC4SIL with the correct IOC4TSIL rear card. Channel mapping and relay voting should be verified against the safety requirement specification (SRS).
- Hot swap and service – The VM600 architecture supports live card replacement, but for safety cards, trips should be inhibited and MOC procedures followed to avoid spurious shutdowns.
- Proof testing – Establish a documented proof‑test interval consistent with your target SIL (commonly 1–2 years). Verify relay actuation, trip logic, and input channel integrity.
- Routine care – Check terminal tightness and connector condition during outages, vacuum dust from the rack, and review event logs. Firmware/config backups should be kept under change control.
Quality & Certifications
- Functional safety: SIL‑rated card set when used with IOC4TSIL; assessed to IEC 61508/61511 (commonly applied for SIL 2 loops).
- Regulatory: CE marking and RoHS compliance are typically available for VM600 modules.
- Manufacturing quality: Produced under ISO 9001 quality systems (typical for Vibro‑Meter products).
- Warranty: 365‑day warranty from us; manufacturer’s standard policies may also apply depending on supply channel.