WOODWARD MRR1-D – Modular Relay Module for Engine/Turbine Control Panels

Brand / Model WOODWARD MRR1-D
HS Code 8537.10 (Boards/panels for electric control, ≤1000 V)
Power Requirements 24 Vdc nominal (typically 18–32 Vdc)
Signal I/O Types Discrete relay outputs; dry contacts (Form A/Form C depending on variant)
Communication Interfaces Hardwired I/O (no fieldbus on most MRR modules)
Operating Temperature Typically -20°C to +60°C (panel-mounted environments)
Installation Method DIN-rail or panel/backplate mount (depends on enclosure build)
Dimensions & Weight Compact module form factor; approx. 0.4–0.6 kg (varies by revision)

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

WOODWARD MRR1-D – Modular Relay Module for Engine/Turbine Control PanelsOIP-16

The WOODWARD MRR1-D is a compact relay module that’s typically used to expand hardwired I/O and interlocks in engine, turbine, and generator control panels. From my experience, it’s a straightforward way to add reliable, isolated relay outputs around a main governor or protection system—without overcomplicating the cabinet. You might notice that it integrates especially well in retrofit projects where dry-contact logic is still the preferred method for permissives, trips, and status signaling.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week for in-stock items; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Dedicated relay outputs – Dry-contact outputs for permissives, trips, alarms, and status signals in many control schemes.
  • Galvanic isolation – Typically isolated channels to reduce noise coupling into sensitive speed or actuator circuits.
  • 24 Vdc control power – Nominal 24 Vdc supply, which fits most industrial control cabinets without extra conversion.
  • Panel-friendly wiring – Pluggable terminal style on many units makes replacement faster and reduces downtime.
  • Status indication – On-board LEDs (where fitted) make point-by-point troubleshooting more intuitive.
  • Rugged for industrial environments – Designed for continuous service in equipment rooms and skid enclosures.

Technical Specifications

Brand / Model WOODWARD MRR1-D
HS Code 8537.10 (Boards/panels for electric control, ≤1000 V)
Power Requirements 24 Vdc nominal (typically 18–32 Vdc)
Signal I/O Types Discrete relay outputs; dry contacts (Form A/Form C depending on variant)
Communication Interfaces Hardwired I/O (no fieldbus on most MRR modules)
Operating Temperature Typically -20°C to +60°C (panel-mounted environments)
Installation Method DIN-rail or panel/backplate mount (depends on enclosure build)
Dimensions & Weight Compact module form factor; approx. 0.4–0.6 kg (varies by revision)

Note: Specific values can vary by hardware revision. If a particular rating matters for your project (contact type or coil burden, for example), we can verify against the exact part/build code before shipping.

Application Fields

  • Gas/steam turbine panels – trip relays, permissives, and status fan-outs alongside governors and overspeed systems.
  • Engine-generator sets – start/stop logic, breaker status relays, and alarm signaling to DCS/SCADA.
  • Compressor and pump skids – safe interlocks and ESD handshakes in oil & gas and process facilities.
  • Industrial boilers and balance-of-plant – hardwired protection layers where simplicity and reliability matter.

Advantages & Value

  • Reliability you can count on – Stable coil drive and isolation help reduce nuisance trips in noisy electrical environments.
  • Easy retrofit – Works with existing 24 Vdc control power and dry-contact logic; typically no PLC code changes needed.
  • Lower downtime – Quick terminal access and clear status indication simplify troubleshooting during outages.
  • Broad compatibility – Dry contacts tie in cleanly with DCS, ESD, and governor systems from multiple vendors.
  • Spares strategy – Standardized relay modules make it easier to pool spares across multiple sites.

One thing I appreciate is how predictable the wiring is. A maintenance lead at a combined-cycle plant told us their team swapped an older relay pack for an MRR1-D in under an hour, then verified every interlock through the front LEDs before start—no surprises.

Installation & Maintenance

  • Cabinet environment – Mount in a clean, ventilated control cabinet; maintain ambient within the stated operating range.
  • Power & grounding – Use a regulated 24 Vdc supply; bond cabinet ground and keep relay wiring separate from high-noise VFD or ignition leads.
  • Wiring – Follow proper wire gauge and torque specs; label contacts for each permissive/trip path to aid commissioning.
  • Protection – Add surge protection on supply lines in sites with frequent switching transients.
  • Routine checks – Quarterly visual inspection of terminals; annual relay function test and contact resistance check; clean dust with dry air.
  • Firmware/records – If your unit has a programmable variant, keep a revision note with cabinet documentation to speed future replacements.

Quality & Certifications

  • CE compliant (typical for Woodward control modules)
  • UL/cUL recognition on many variants used in North America
  • RoHS compliance for electronic assemblies where applicable
  • Manufacturer quality system: ISO 9001
  • Warranty: 365 days from delivery
Need exact contact ratings or a specific build code? Share your panel photo or part label and we’ll match the MRR1-D variant and confirm coil burden, contact form, and mounting in writing before shipment.

Reviews

There are no reviews yet.

Be the first to review “WOODWARD MRR1-D – Modular Relay Module for Engine/Turbine Control Panels”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products