Description
Woodward MSLC-2 8440-1977 – Mains Synchronizer & Load Control for Reliable Utility Paralleling
The Woodward MSLC-2 (model 8440-1977) is built for one job: synchronizing generators to the utility and managing real/reactive power with stability. From my experience, it’s the piece you add when you need consistent import/export control, soft transfer, and clean coordination with your switchgear—without turning the project into a science experiment. It typically pairs well with generator controllers (like Woodward’s DSLC-2) to form a complete mains–gen-set solution for hospitals, data centers, and heavy industry.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- Automatic mains synchronization – Matches phase, frequency, and voltage to permit safe breaker closure to the grid.
- Import/Export (kW) control – Maintains a targeted power flow with the utility for peak shaving or base-loading.
- PF / VAR management – Controls reactive power to hold a desired power factor or vars against the mains.
- Soft loading and unloading – Smooth transitions reduce mechanical stress and flicker during transfers.
- Dead-bus recognition & sync check – Extra permissives help protect switchgear and prevent misoperation.
- Open or closed-transition transfer – Configure per site standard and interlock logic in the switchgear.
- SCADA connectivity – Ethernet-based connection for monitoring, setpoint adjustment, and remote integration.
- Works in Woodward ecosystems – Typically deployed with generator-side controllers to complete the paralleling scheme.
Technical Specifications
| Brand / Model | Woodward MSLC-2 – 8440-1977 |
| HS Code | 9032.89 (Automatic regulating or controlling instruments) |
| Power Requirements | 24 Vdc nominal (typically 18–32 Vdc) |
| Operating Temperature | -20°C to +70°C (industrial cabinet environment) |
| Signal Input / Output Types | Three-phase voltage sensing (PT) for mains and generator; current inputs via CT (1 A / 5 A typical); digital status inputs; relay outputs for breaker/permission commands; analog references for power control in many cases. |
| Communication Interfaces | Ethernet 10/100Base-T for configuration and SCADA integration (e.g., Modbus TCP) |
| Installation Method | Back-panel mounting inside low-voltage switchgear/control cabinets |
Application Fields
You’ll typically see the MSLC-2 at the mains side of:
- Utility paralleling switchgear for hospitals, airports, and data centers
- Industrial plants and refineries with peak shaving or base-loading needs
- CHP and cogeneration systems managing grid import/export and PF
- Microgrids requiring controlled transitions and mains support
One thing I appreciate is how calmly it handles load transfers—soft unloading before an open transition, or coordinating a tight closed transition when the utility permits it. A switchgear builder told us their commissioning time dropped because the synchronizer “just matched and closed” repeatedly without chasing.
Advantages & Value
- Reliability – Stable sync and power control logic reduce nuisance trips and breaker mis-operations.
- Compatibility – Fits cleanly into Woodward-based architectures and standard low-voltage switchgear schemes.
- Cost Savings – Precise import/export and PF control can cut demand charges and penalties in many cases.
- Faster Commissioning – Clear permissives, sync-check, and soft transfer behaviors shorten on-site tuning.
- Lifecycle Support – Mature platform with long-term parts availability and firmware support from Woodward.
Installation & Maintenance
- Cabinet & environment – Mount on a clean, rigid backplate inside a ventilated cabinet; avoid condensation and corrosive atmospheres.
- Power & grounding – Feed a stable 24 Vdc supply; bond to protective earth; separate signal and power wiring to limit noise.
- CT/PT wiring – Observe polarity and burden limits; use shielded cabling and route away from high-current buswork.
- Breaker interlocks – Implement sync-check and permissive logic in the scheme; verify open/closed transition settings before live tests.
- Routine checks – Periodically clean terminals, verify kW/kVAR setpoints, confirm PF targets, and back up configuration.
- Firmware & tools – Keep controller firmware current and document any parameter changes during maintenance windows.
Quality & Certifications
- Certifications – CE; UL/cUL; RoHS compliant (typical for this Woodward family)
- Warranty – 12 months coverage as stated above
- Manufacturing – Industrial-grade design for mains paralleling duty
Related Products & Typical Pairings
- Woodward DSLC-2 – Generator-side load sharing and sync controller working in tandem with MSLC-2 at the mains.
- Woodward SPM-D2 – Compact synchronizer for single-machine applications or smaller panels.
- Woodward easYgen series – Generator controls when an integrated genset controller is preferred, with MSLC-2 as the mains interface.






Reviews
There are no reviews yet.