Yokogawa AAI141-H00K4A00 – Multi‑Channel Analog Input Module for stable 4–20 mA measurement in CENTUM systems

1 Brand: Yokogawa
2 Model: AAI141-H00K4A00
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Yokogawa AAI141-H00K4A00 – Multi‑Channel Analog Input Module for stable 4–20 mA measurement in CENTUM systemsAAI141-H00K4A00

The Yokogawa AAI141-H00K4A00 is an Analog Input (AI) module designed for the CENTUM VP/CS 3000 family’s FIO base. From my experience, it’s the go-to choice when you need dependable, multi-channel 4–20 mA acquisition from field transmitters without babysitting the signal chain. You might notice that it slots directly onto the FIO baseplate and communicates via the system backplane—no separate fieldbus card or external power for the module itself.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: In-stock items ship in about 1 week; latest no more than 1 month
  • Payment: 50% advance; full payment prior to delivery
  • Express options: FedEx, UPS, DHL
  • Every unit is inspected, packed for industrial transit, and supported by our technical team for commissioning questions.

Key Features

  • Multi‑channel 4–20 mA inputs – Suitable for typical transmitter signals across process units; reduces I/O footprint in crowded cabinets.
  • Backplane-powered module – Draws power from the FIO baseplate, so there’s no separate supply to cable or fuse for the card itself.
  • Robust noise immunity – Designed for industrial environments with good common‑mode rejection and stable readings in the presence of VFDs and heavy loads.
  • Health diagnostics – Channel status and range checks help maintenance teams pinpoint wiring issues faster (open loop, out‑of‑range conditions, etc.).
  • Straightforward integration – Works within the CENTUM VP/CS 3000 FIO architecture; engineering is typically quick for replacement or expansion projects.
  • On‑line serviceability (system‑dependent) – In many cases, modules can be replaced during operation when proper redundancy and procedures are in place.

Technical Specifications

Brand / Model Yokogawa AAI141-H00K4A00
HS Code 8538.90 (Parts suitable for apparatus of 8537)
Function Analog Input module for 4–20 mA transmitters (multi‑channel)
Power Requirements Powered via FIO backplane; no separate external supply for the module
Signal Input Type 4–20 mA analog inputs; loop power provided externally to the field transmitter
Communication Interface Backplane/FIO to CENTUM controller or node unit (no separate fieldbus on the card)
Operating Temperature 0 to 55 °C (typical cabinet conditions)
Installation Method Plugs into Yokogawa FIO baseplate; mounted inside a control cabinet (DIN/panel baseplate assembly)

Application Fields

This module fits well wherever stable analog measurement is critical. Typical deployments include:

  • Refining and petrochemicals – temperature, pressure, and flow transmitters across units
  • Chemicals and specialty process – batch reactors and utility skids
  • Power & utilities – boiler and balance‑of‑plant analogs, make‑up water systems
  • Water & wastewater – level, turbidity, and dosing control loops
  • Pharmaceuticals – environmental monitoring and CIP/SIP skids

A maintenance lead at a midstream facility told us they swapped in AAI141 cards during a phased I/O refresh; commissioning was uneventful, and they appreciated the predictable channel behavior with mixed transmitter brands.

Advantages & Value

  • Reliability – Yokogawa I/O tends to run for years; fewer nuisance trips and callouts in many cases.
  • Compatibility – Native fit for CENTUM VP/CS 3000 FIO; straightforward migration or expansion without rethinking the cabinet design.
  • Lifecycle and spares – Stable supply and broad installed base make it easier to standardize spares across units.
  • Cost efficiency – Multi‑channel density helps contain cabinet space and wiring time, which usually trims project hours.
  • Technical support – We provide pre‑shipment checks and can share wiring/application tips that shorten commissioning.

Installation & Maintenance

  • Cabinet environment – Keep within 0–55 °C, provide ventilation, and avoid mounting near VFDs or heavy power lines where possible.
  • Wiring practices – Use shielded twisted pair for analog loops; land shields at a single, clean ground; segregate from high‑voltage runs.
  • Loop power – Transmitters typically require external 24 VDC loop power; match transmitter polarity and the card’s channel terminals.
  • Commissioning – Verify range and scaling in engineering tools; perform a quick loop check (zero/span) to confirm integrity.
  • Serviceability – With proper system redundancy, on‑line replacement is often possible; follow site MOC and vendor procedures.
  • Routine care – Periodically inspect terminal tightness, clean dust from the cabinet, and document any firmware or configuration updates in the control strategy.

Quality & Certifications

  • Typically conforms to CE and UL; RoHS compliance on recent production
  • Manufactured by Yokogawa for industrial control environments
  • Backed by our 365‑day warranty and pre‑shipment functional checks

If you’re standardizing spares or planning a small I/O expansion, the AAI141-H00K4A00 tends to be a low‑risk, plug‑and‑run option in CENTUM systems. Let me know the target channel count and any special loop details (e.g., intrinsic safety barriers, remote marshalling), and I’ll match the exact variant and terminals accordingly.