YOKOGAWA PW441-10 System Power Supply Module – Stable 24 VDC backplane power for Yokogawa control racks

1 Brand: YOKOGAWA
2 Model:  PW441-10
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

YOKOGAWA PW441-10 System Power Supply Module – Stable 24 VDC backplane power for Yokogawa control racksyokogawa_pw441-10_power_supply_module_3yokogawa_pw441-10_power_supply_module-1

The YOKOGAWA PW441-10 is a dedicated system power module designed to feed the internal DC rails of Yokogawa control racks. From my experience, it’s the kind of drop-in power supply you pick when you want long-term stability, clean power to the backplane, and straightforward redundancy options without reshaping your cabinet layout. You might notice that it’s typically used to replace a failed PSU or to build a redundant pair in a running node to cut downtime risk.

Company’s Order Placement Process and Guarantees

  • Warranty period: 365 days
  • Delivery time: 1 week for in-stock; no more than one month at the latest
  • Payment method: 50% advance payment; full payment for delivery
  • Express delivery methods: FedEx, UPS, DHL

Key Features

  • 24 VDC system input – Feeds the controller backplane with regulated DC power; typically used with 24 VDC plant supplies or UPS-backed rails.
  • Redundancy-ready design – In many cases can be used in a dual configuration for N+1 power redundancy, reducing the impact of a single PSU failure.
  • Front-panel diagnostics – Status LEDs for quick checks during commissioning or troubleshooting.
  • Rack-compatible form factor – Fits the designated power slot of compatible Yokogawa racks; no custom brackets in normal situations.
  • Industrial temperature capability – Typically supports control-room temperatures common to DCS/PLC enclosures.
  • Low maintenance – No signal wiring; periodic visual checks and dust cleaning are usually enough.

Technical Specifications

Brand / Model YOKOGAWA / PW441-10
HS Code 8504.40 (Static converters, power supplies)
Power Requirements 24 VDC nominal input (typical usable range 21.6–26.4 VDC); provides regulated backplane power to the system rack
Operating Temperature Typically 0–55°C, non-condensing ambient in control cabinet environments
Signal I/O Types None (power supply module; no process I/O)
Communication Interfaces None (status indicated via front LEDs)
Installation Method Plug-in module for compatible Yokogawa rack; supports redundant pairing where specified by the rack/controller

Application Fields

This module is used in control cabinets powering Yokogawa racks in process industries. Typical scenarios include:

  • DCS/SIS nodes in oil & gas, petrochemical, and refining units
  • Power generation and utilities control rooms
  • Water and wastewater facilities upgrading legacy power modules
  • Pharmaceutical and fine chemical plants aiming for PSU redundancy

One thing I appreciate is how quickly maintenance teams can recover a node by swapping the power module. A maintenance lead at a gas processing site told me they restored a controller bay in under 10 minutes after slotting in a PW441-10 and rebalancing the redundant pair.

Advantages & Value

  • Reliability – Clean, stable backplane power that typically reduces nuisance trips and intermittent faults linked to aging PSUs.
  • Compatibility – Designed for Yokogawa racks using the PW441-10 slotting scheme; keeps your wiring intact and avoids panel rework.
  • Cost savings – Redundant pairing and quick replacement keep downtime and callout hours to a minimum.
  • Support – We help verify rack compatibility and redundancy setup so you receive the right unit the first time.

Installation & Maintenance

  • Cabinet & environment – Install in a clean, ventilated control cabinet. Maintain ambient within typical 0–55°C and avoid condensation.
  • Power wiring – Use a stable 24 VDC source (preferably UPS-backed). Follow Yokogawa torque specs and protective earth grounding practices.
  • Redundancy – For N+1 setups, pair two units according to the rack/controller manual and verify load-sharing and status LEDs after power-up.
  • Hot swap – Many racks support online replacement; if unsure, schedule a brief downtime window and follow site LOTO procedures.
  • Routine checks – Inspect LED status during rounds, clean dust filters/vents, and confirm terminal tightness during periodic PMs.

Quality & Certifications

  • Typically conforms to industrial EMC and safety standards; CE/UL compliance is common on Yokogawa rack modules (verify per your exact revision).
  • RoHS alignment is typical for current-production units.
  • Warranty: 365 days coverage as stated above.

Tip: If you are replacing an existing unit, share the rack/controller part number or a photo of the nameplate. It helps confirm redundancy options and the correct -10 variant for your cabinet.

Reviews

There are no reviews yet.

Be the first to review “YOKOGAWA PW441-10 System Power Supply Module – Stable 24 VDC backplane power for Yokogawa control racks”

Your email address will not be published. Required fields are marked *