Yokogawa YHC4150X – Handheld HART Communicator for Field Device Configuration and Maintenance

1 Brand: Yokogawa
2 Model: YHC4150X
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Yokogawa YHC4150X – Handheld HART Communicator for Field Device Configuration and MaintenanceYHC4150X

The Yokogawa YHC4150X is a portable HART communicator designed for everyday commissioning, configuration, and troubleshooting of HART-enabled transmitters and positioners in plants and on job sites. From my experience, technicians like it because it typically supports a broad HART DD library, handles device ranging and tag edits quickly, and makes it easy to poll devices on a live 4–20 mA loop without dragging a laptop to the field. You might notice that it feels straightforward—connect across the loop, read the device, adjust what you need, save the changes, and move on to the next instrument.

Order Placement Process and Guarantees

    • – Warranty period: 365 days
    • – Delivery time: 1 week for in-stock items; no more than one month at the latest
    • – Payment: 50% advance payment; full payment prior to delivery
    – Express delivery: FedEx, UPS, DHL

Key Features

  • Universal HART support – Typically works with HART devices using their native DDs, so you see the right parameters and methods for each instrument.
  • Fast online/offline configuration – Read device data on a live loop or stage changes offline and push them when you connect.
  • Device diagnostics – Polls devices, reads status and diagnostics, and helps identify wiring or loop issues quickly.
  • Loop-friendly connections – Connects across the 4–20 mA loop using HART Bell 202 FSK; in many cases a 250 Ω loop resistance is required for stable comms.
  • Field-ready design – Rugged handheld form factor with a backlit display and tactile keypad that seems to hold up well in day-to-day use.
  • Updatable firmware/DD library – Typically updated via USB, keeping the communicator aligned with newer device DDs and fixes.
  • Hazardous area suitability – The YHC4150X is commonly supplied with intrinsic safety approvals for use in hazardous locations; always check the nameplate on your unit.

Technical Specifications

Item Details
Brand / Model Yokogawa YHC4150X (Handheld HART Communicator)
HS Code 9031.80.0000 (Measuring or checking instruments, other)
Power Requirements Battery-powered handheld; typically supplied with a rechargeable pack and external AC adapter/charger.
Dimensions & Weight Handheld form factor; approx. 250 × 110 × 50 mm; typically under 1 kg (varies slightly by configuration).
Operating Temperature Typically 0 to +50 °C; non-condensing humidity environment recommended for best readability and battery life.
Signal Input/Output Types HART Bell 202 FSK over 4–20 mA loop; connects across device or marshalling terminals. A total loop resistance near 250 Ω is commonly required for communication.
Communication Interfaces HART clip leads/terminals for field connection; USB device port for firmware/DD updates and data transfer.
Installation Method Portable handheld; no fixed installation. Connect across the loop at the instrument, marshalling panel, or test jacks.

Related and Supporting Products

  • Yokogawa YHC5150X – Newer generation handheld; in many cases adds a more modern UI, faster performance, and expanded DD support. A good choice if you’re standardizing on new units.
  • Emerson AMS Trex – Alternative platform with HART (and FOUNDATION Fieldbus on certain versions); rugged but larger and typically higher cost.
  • USB HART Modem (e.g., HM-USB-ISO type) – For laptop-based HART configuration. Great when you prefer full-screen configuration software, but less convenient in the field.
  • 250 Ω Loop Resistor – Useful when your loop doesn’t meet HART resistance requirements; often needed during bench work.
  • Portable 24 V Loop Power Supply – Handy for bench configuration or when the plant loop isn’t powered.
  • Lead sets and clip adapters – Replacement or extended leads to reach terminals in tight cabinets.

Installation & Maintenance

  • Environment – Use in clean, dry areas when possible. If you’re in bright sun or a dark rack room, the backlight helps but viewing angle matters a bit.
  • Wiring practice – Connect across the 4–20 mA loop with proper polarity. If comms are unstable, check total loop resistance and add a 250 Ω resistor if required.
  • Cabinets and access – When working in control cabinets, maintain clearance around live terminals, avoid stress on terminal blocks, and keep lead routing tidy to prevent accidental shorts.
  • Hazardous locations – Only use units with the appropriate intrinsic safety markings in classified areas. Verify the exact approvals on the YHC4150X nameplate.
  • Routine care – Keep firmware and DD libraries up to date via USB. Clean the keypad and screen with a soft, slightly damp cloth. Battery health typically improves if you avoid deep discharges.
  • Data and documentation – Save device configurations after changes. It seems trivial, but having a backup speeds up replacements and audits.

Quality & Certifications

  • CE conformity and RoHS compliance are typically provided for this series.
  • Intrinsic Safety (ATEX/IECEx, FM/cCSAus) versions are commonly available for the YHC4150X; verify exact markings on your unit.
  • Manufacturer’s standard quality system (ISO-based production). Warranty from us: 365 days.

One thing I appreciate is how quickly a communicator like the YHC4150X lets you range a transmitter during start-up, then save the as-left data right away. Field feedback we hear often: “It just connects and works—even on older loops—once we add the 250 ohm resistor.” If you need help confirming DD support for a specific device revision, share the tag/model and we’ll check compatibility before shipping.

Reviews

There are no reviews yet.

Be the first to review “Yokogawa YHC4150X – Handheld HART Communicator for Field Device Configuration and Maintenance”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products