GE DS200TCRAG1ACC – Thermocouple Input Board for Speedtronic Mark V Temperature Acquisition

1 Brand: GE
2 Model: DS200TCRAG1ACC
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

GE DS200TCRAG1ACC – Thermocouple Input Board for Speedtronic Mark V Temperature AcquisitionDS200TCRAG1ACC

The GE DS200TCRAG1ACC is a Thermocouple Input Board engineered for Speedtronic Mark V control systems. From my experience, this board typically handles multi-channel thermocouple signals with cold-junction compensation, linearization, and fault detection, then streams clean, time-coherent temperature data to the Mark V backplane. If you’re maintaining a gas/steam turbine, HRSG, or high-temperature process line, this is one of those plug-in spares that keeps trips down and diagnostics straightforward.

Our Order Process & Guarantees

  • Warranty: 365 days
  • Lead time: 1 week if in stock; no more than one month at the latest
  • Payment terms: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL
  • Every unit is function-tested prior to shipment and packed for ESD protection

Key Features

  • Thermocouple signal conditioning – Accepts low-level mV inputs from common TC types (J, K, T, E, R, S, B) for turbine and process measurements.
  • Cold-junction compensation – CJC circuitry helps maintain accuracy across cabinet temperature changes.
  • Linearization and fault detection – On-board processing typically provides open-circuit detection and stable scaling to engineering units.
  • High-noise immunity – Input filtering and board layout designed for EMI/RFI resilience in turbine enclosures.
  • Backplane integration – Direct interface to the Mark V backplane for deterministic data transfer; no external wiring beyond the terminal board.
  • Field serviceability – Plug-in replacement with captive hardware; typically no recalibration required after swap.
  • Status indication – You might notice service LEDs that make field diagnostics faster.
  • Drop-in compatibility – Designed for Speedtronic Mark V racks with the matching thermocouple terminal board.

Technical Specifications

Brand / Model GE DS200TCRAG1ACC
HS Code 8538.90 (Parts for electrical control apparatus)
Main Function Thermocouple input/conditioning module for Speedtronic Mark V systems
Power Requirements Supplied via Mark V backplane; no external power needed (typically +5 V and analog rails provided by rack)
Operating Temperature 0 to 60°C typical cabinet environment; 5–95% RH non‑condensing
Signal Input/Output Types Differential thermocouple inputs (Types J/K/T/E/R/S/B), cold-junction compensation; digital data to backplane
Communication Interfaces Mark V backplane bus (not user-configurable I/O ports)
Installation Method Plug-in PCB into Mark V rack with mating thermocouple terminal board; secured via standard board retainers
Form Factor Standard DS200 board format for Speedtronic Mark V

Application Fields

This board is commonly used wherever reliable, multi-point temperature monitoring feeds the Mark V control:

  • Gas and steam turbine exhaust, bearing, and casing temperature surveillance
  • HRSG and boiler tube temperature mapping
  • Industrial furnaces, reformers, and kilns requiring stable high-temperature measurement
  • Compressor trains and balance-of-plant thermal protection

“Swap time was under 30 minutes and our drift issue disappeared,” noted a maintenance lead at a combined-cycle plant after replacing a TCRA board during a scheduled outage.

Advantages & Value

  • Reliability – Proven GE hardware with robust filtering helps avoid nuisance trips in electrically noisy rooms.
  • Compatibility – Drop-in fit for Mark V with the matching terminal board; no wiring rework in most cases.
  • Reduced downtime – Quick board-level replacement means faster recovery from channel faults.
  • Support – From part selection to commissioning advice, we typically help verify revisions and backplane compatibility before shipment.
  • Lifecycle savings – Stable temperature inputs contribute to better tuning, fewer false alarms, and less wear on the machine.

Installation & Maintenance

  • Cabinet & environment – Install in a clean, ventilated Mark V enclosure. Maintain airflow and keep away from high-voltage cabling to limit induced noise.
  • Wiring practices – Use matching thermocouple extension wire and correct polarity. Route TC pairs separately from power conductors; land shields at a single point to minimize ground loops.
  • ESD handling – Use a grounded wrist strap, power down the rack, and allow discharge time before removal or insertion.
  • Commissioning – After installation, verify each channel with a dry-well or simulator. You might notice that open-circuit detection quickly flags miswired points.
  • Routine care – Periodic connector re-seating, light dust removal with dry air, and point-to-point checks during outages are usually sufficient. Firmware changes are not typically required for this board type.

Quality & Certifications

  • Manufacturing quality: GE production under ISO 9001 quality systems (typical for this product family)
  • UL/cUL: Generally recognized as part of the complete control panel assembly
  • CE: System-level CE compliance depends on the overall Mark V cabinet configuration
  • RoHS: Legacy hardware may not be RoHS; compliant alternatives or refurbished options can be discussed
  • Warranty: 365 days replacement/repair coverage from delivery

Related/Supporting Components

  • GE DS200TBTC – Thermocouple terminal board that mates with TCRA; provides field-wiring terminations and local CJC hardware.
  • GE DS200TCQAG1A – Analog/quantizer or controller interface board in the Mark V core; receives processed data from input boards.
  • GE DS200TBCAG1A – Termination board variant often used for field I/O aggregation; useful when expanding or reorganizing wiring.

If you’re unsure about the exact terminal board or revision pairing, share a photo of your existing rack slots and part labels—matching “G” group and revision letters typically avoids compatibility surprises.

Reviews

There are no reviews yet.

Be the first to review “GE DS200TCRAG1ACC – Thermocouple Input Board for Speedtronic Mark V Temperature Acquisition”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products