Description
6SE7031‑7EE85‑0AA0 SIMOVERT MASTERDRIVES Rectifier / Regenerative Unit
Technical Specifications
- Product Model: 6SE7031‑7EE85‑0AA0
- Brand: Siemens
- Warranty: One Year
- Input Voltage: 3‑phase 380‑480 V AC, 50 / 60 Hz mains supply
- Operating Temperature: 0 °C ~ +40 °C (derating above 40 °C)
- Storage Temperature: ‑40 °C ~ +85 °C
- Response Time: Regenerative energy feedback response <5 ms
- Protection Class: IP20 cabinet‑mount chassis unit
- Accuracy Class: High‑performance drive power‑conversion grade
- Output Frequency: Not applicable (common DC‑bus supply)
- Rated Current: 173 A input nominal; 75 kW power rating
- Function: Self‑commutated rectifier‑regenerative power supply unit for SIMOVERT MASTERDRIVES multi‑drive groups; supplies common DC‑bus and feeds braking energy back to mains grid
- Control Interface: CUR control board, PMU local parameter unit, RS485 serial communication port
- Protection: Over‑voltage, under‑voltage, over‑current, over‑temperature, DC‑bus short‑circuit fault protection
- Diagnostics: 7‑segment PMU fault‑code display, internal fault‑history buffer
- Certifications: CE, UL
- Humidity: 5‑95 % RH, non‑condensing
- Weight: 28 kg
- Dimensions: 450 × 360 × 260 mm (H×W×D)

Product Overview
6SE7031‑7EE85‑0AA0 belongs to Siemens SIMOVERT MASTERDRIVES vector‑control family, a regenerative common‑bus rectifier unit for multi‑drive groups in heavy‑industry applications such as metal rolling mills, cranes, test‑stands and extrudersMade-in-Ch…. Instead of dissipating braking energy via brake resistors, it returns regenerative power back to the AC mains network to improve overall system energy efficiency. Equipped with CUR control electronics and PMU local operator panel for parameter setup and fault diagnosis. End‑of‑life drive hardware available as refurbished and tested surplus spare unit for legacy multi‑drive system overhaul projects.
Application Notes
‑ Install inside well‑ventilated electrical cabinet; maintain specified clearance for cooling air flow. ‑ Discharge DC‑bus capacitors completely before opening unit cover for service work. ‑ Match DC‑bus voltage rating to connected inverter modules. ‑ Typical deployment: steel‑plant multi‑drive group rectifier‑unit spare‑part stocking.






Reviews
There are no reviews yet.