Description
Product Overview
The SERVOSTAR 614 is a digital servo amplifier from Kollmorgen’s S600 series: a 14 A RMS continuous, 28 A peak drive that runs directly off a grounded three-phase 230–480 V AC supply with an integrated line filter and integrated brake resistor, so no external transformer, filter panel or braking unit is needed on a 10 kVA axis. It closes current, velocity and position loops fully digitally — current loop at 62.5 µs, position loop at 250 µs — and includes a positioner with 255 motion blocks, electronic gearing and registration control, which lets it run a standalone indexing axis without a separate motion controller. Feedback support is broad (resolver, sine-cosine encoder with EnDat/HiPERFACE/BiSS, incremental AquadB), and CANopen is on board with optional DeviceNet, PROFIBUS, SERCOS, SynqNet or EtherCAT cards. On a packaging, printing or machine-tool axis where the original amplifier has failed, this is the direct replacement: same 100 mm width, same power terminals, same parameter set.
Technical Specifications
- Brand: Kollmorgen
- Model: SERVOSTAR 614 (S614), SERVOSTAR 600 series, standard version
- Input / Output (power): 3-phase 230 V -10% to 480 V +10%, 50 Hz; 208 V -10% to 480 V +10%, 60 Hz; TN or TT network with grounded neutral, max. 42,000 A RMS symmetrical; single-phase operation possible for setup
- Rated Input Power (S1): 10 kVA at 480 V AC
- Output Current: 14 A RMS continuous (±3%); 28 A RMS peak (approx. 5 s)
- Output Stage Switching Frequency: 8 kHz standard (16 kHz permissible up to 400 V DC bus, with rated current reduced to 7.7 A at 400 V)
- DC Bus Link: 290–675 V DC rated; parallel DC bus linking permitted (sum of rated currents of linked S601–620 amplifiers must not exceed 40 A)
- Load Inductance: 2.5 mH minimum, 15 mH maximum
- Power Loss at Rated Current: 160 W
- Regenerative Braking: Internal brake resistor 200 W continuous; external brake resistor option 1.5 kW continuous / 21 kW peak, 33 Ω
- Control Loops: Digital current controller 62.5 µs (space-vector PWM), velocity controller 62.5 µs adaptable, position controller 250 µs; velocity loop bandwidth up to 400 Hz; current controller bandwidth > 1.2 kHz
- Input / Output (signals): 2 analog setpoint inputs ±10 V (14-bit / 12-bit resolution, 20 kΩ input resistance, ±10 V common-mode); digital inputs and open-collector outputs per IEC 61131; BTB/RTO relay contact 30 V DC / 42 V AC at 500 mA
- Auxiliary Supply: 24 V DC (-0%/+15%), 1 A isolated (3 A when a motor holding brake is used); brake output current 0.15–2 A
- Feedback: Resolver (up to 36 poles), ComCoder, incremental or sine encoder with Hall, sine encoder with EnDat / HiPERFACE / BiSS, sine encoder without data track, incremental AquadB
- Communication: CANopen integrated (default 500 kBaud); isolated RS-232; integrated pulse-direction interface; optional expansion cards for DeviceNet, PROFIBUS DP, SERCOS, SynqNet, EtherCAT or additional I/O
- Positioning Functions: 255 motion blocks, velocity profiles, registration control, jerk limiting, chained/absolute/relative moves, multiple homing modes, incremental or absolute encoder emulation
- Operating Temp: 0 to +45 °C at rated data; +45 to +55 °C with 2.5% derating per K; relative humidity 85% non-condensing; altitude up to 1000 m without restriction (1.5%/100 m derating above)
- Protection / Standards: IP20, pollution degree 2, overvoltage category III per EN 61800-5-1; CE, UL, cUL; integrated line filter to C3
- Dimensions / Weight: 275 mm height x 100 mm width x 265 mm depth (273 mm with connectors); approx. 7.5 kg
- Warranty: One Year
- Condition: 100% New & Original
Key Notes
- This drive has no safety functionality to IEC 61800-5-2 — no STO input. A machine that relied on STO on the failed amplifier cannot be restored to the same safety architecture by fitting this unit; the safety function has to come from an upstream contactor or a different drive model.
- The 16 kHz option halves the usable continuous current at 400 V (7.7 A), so do not simply raise the switching frequency to reduce motor noise on a fully loaded axis.
- Leakage current to PE exceeds 3.5 mA: the PE conductor must be doubled, or a cable larger than 10 mm² used, per IEC 61800-5-1.
- The amplifier can only be operated inside a closed switchgear cabinet with the specified ventilation, and the motor rated voltage must be at least as high as the DC bus voltage.