57C414 | rack‑mounted Modbus interface gateway built

$2,355.00

  • Product Model: 57C414
  • Brand: Reliance Electric
  • Warranty: One Year
  • Input Voltage: 5 VDC AutoMax rack backplane
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: -40 °C to +85 °C
  • Response Time: ≤ 12 ms Modbus message processing cycle
Categories: Tags: SKU: 57C414
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

  • Product Model: 57C414
  • Brand: Reliance Electric
  • Warranty: One Year
  • Input Voltage: 5 VDC AutoMax rack backplane
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: -40 °C to +85 °C
  • Response Time: ≤ 12 ms Modbus message processing cycle
  • Protection Class: IP00 (rack‑mount PCB module)
  • Accuracy Class: N/A (communication gateway module)
  • Output Frequency: N/A
  • Rated Current Range: 0‑450 mA backplane consumption
  • Communication Interface: RS‑232 Modbus gateway port, AutoMax proprietary backplane connector
  • Supported Protocols: Modbus RTU, Modbus ASCII, AutoMax backplane protocol
  • Overload Capacity: Electronic backplane over‑current protection
  • Dimensions: 340 mm × 190 mm × 30 mm

Product Overview

The Reliance Electric 57C414 is a rack‑mounted Modbus interface gateway built for the Reliance AutoMax control platform. This module bridges AutoMax processor racks to external Modbus‑capable hardware, emulating Modicon 584 register table mapping for seamless data exchange between dissimilar automation systems. It transfers discrete and register‑based process data, handles protocol translation locally on‑board, and provides front‑panel thumbwheel switches for drop‑node address configuration plus LED fault status indicators for quick diagnostic visibility. It addresses integration pain points including limited native Modbus support on legacy AutoMax controllers, complex custom driver development, and lack of direct interoperability with third‑party drives, meters and SCADA hosts. Control system integrators, plant maintenance technicians and legacy‑system support engineers benefit from this hardware; it eliminates custom software gateways, simplifies multi‑vendor system interconnection, and delivers real‑time fault indication to reduce commissioning and troubleshooting downtime.
YPK112A-3ASD573001A13-2

Application Scenarios

  • Manufacturing Drive System Integration: Installed inside AutoMax control racks to connect the host controller to Modbus‑enabled variable‑speed drives. The gateway passes speed set‑points, feedback values and drive fault codes between the AutoMax logic and motor drives without intermediate conversion hardware.
  • Legacy Plant SCADA Interfacing: Acts as protocol translator for older AutoMax installations communicating with Modbus‑based supervisory systems. It maps internal AutoMax variables into standard Modbus register space, allowing existing SCADA platforms to read process values and send operator commands.
  • Industrial Retrofit Spare Replacement: Used as direct drop‑in spare for ageing AutoMax racks. Matching original backplane form‑factor and protocol handling means replacement can be completed without modifying application logic or external