Description
1. Product Title
Emerson DeltaV SS6501T01‑ Redundant CSLS CHARM Smart Logic Solver Copper Assembly
2. Product Overview
The SS6501T01 is a complete pre‑assembled redundant CSLS (CHARM Smart Logic Solver) unit for Emerson DeltaV SIS safety‑instrumented systems with copper‑based safety network interfaces. This assembly contains dual SIL‑3 rated CSLS logic solver boards, dual power supply modules and a common carrier baseplate, adopting 1oo2D fault‑tolerant architecture for safety logic execution. It supports up to 96 LS‑CHARM safety I/O channels in mixed AI/AO/DI/DO configurations, delivering fully redundant communication path from safety I/O CHARMs to the DeltaV SIS host system. Comprehensive built‑in self‑diagnostics detect hardware faults, communication failures and field‑wiring anomalies. Hot‑swappable components allow online module replacement without safety‑system shutdown. It executes ESD, fire‑gas and process interlock safety functions, meets IEC 61508 SIL‑3 requirements, and reduces risk of spurious trips and loss‑of‑safety‑function in hazardous process plants.
3. Technical Specifications
- Brand: Emerson DeltaV
- Model: SS6501T01
- Warranty: One Year
- Condition: 100% New & Original
- Architecture: 1oo2D redundant dual‑CSLS logic solver assembly
- Safety Rating: IEC 61508 SIL‑3 certified
- Max LS‑CHARM Capacity: 96 safety CHARM channels, mixed I/O type support
- Communication: Dual copper LSN safety network Ethernet ports (twisted‑pair CAT6)
- Power Supply: Dual integrated power modules, nominal 24 VDC system supply
- Feature Set: Full hardware self‑diagnostics, hot‑swap capable, event & fault time‑stamping, plug‑and‑play carrier baseplate
- Mounting: Rack‑slot installation inside DeltaV SIS marshalling cabinet
- Operating Temp: ‑20 °C ~ +65 °C
- Humidity: 5‑95 % RH non‑condensing
- Enclosure Rating: IP20 (cabinet‑only installation)
- Weight: Approx 3.1 kg
- Compliance: IEC 61511, FMEDA safety assessed, CE, UL‑cUL

5. Application Scenarios
- Oil & Gas On‑site & Offshore Platform SIS: Installed in DeltaV SIS marshalling racks to run emergency shutdown logic for compressors, separators and well‑head safety interlock systems.
- Petrochemical Plant Safety Instrumented System: Deployed for reactor and fractionation‑unit protection, executing SIL‑3 interlock and trip logic with LS‑CHARM electronic marshalling I/O.
- Chemical & Combined‑Cycle Power Facility: Used for burner management, boiler protection and process safety interlocks, providing fault‑tolerant safety logic with flexible mixed‑safety‑I/O channel configuration.