TRICONEX 5411H | fiber optic remote I/O extender module

$3,560.00

  • Product Model: TRICONEX 5411H
  • Brand: Triconex (Schneider Electric)
  • Warranty: One Year
  • Input Voltage: 5 VDC backplane powered, dual redundant power regulation
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: -40 °C to +85 °C
Categories: Tags:
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

Technical Specifications

  • Product Model: TRICONEX 5411H
  • Brand: Triconex (Schneider Electric)
  • Warranty: One Year
  • Input Voltage: 5 VDC backplane powered, dual redundant power regulation
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: -40 °C to +85 °C
  • Response Time: Deterministic communication latency ≤ 2 ms
  • Protection Class: IP20, rack-mounted PCB with conformal coating
  • Accuracy Class: N/A (Fiber Optic Remote I/O Extender Module)
  • Output Frequency: N/A
  • Rated Current Range: Module consumption ≤ 320 mA
  • Communication Interface: Dual redundant fiber optic ports (multi-mode)
  • Supported Protocols: Tricon proprietary Remote I/O extender protocol, TMR backplane bus
  • Overload Capacity: 2 kV ESD protection; optical interface electrically isolated from field circuits
  • Dimensions: 340 mm × 185 mm × 32 mm (single Tricon chassis slot)
  • TRICONEX 5411H |  fiber optic remote I/O extender module

Product Overview

The TRICONEX 5411H is a fiber optic remote I/O extender module built for the Tricon Triple Modular Redundant (TMR) safety control platform. It creates galvanically isolated long-distance communication links between the main Tricon host chassis and remote expansion I/O racks, eliminating ground loop interference and electrical noise common in industrial plant environments. Dual redundant optical ports support fault-tolerant data transmission; if one fiber path fails, the second channel maintains continuous I/O data exchange without disrupting safety logic execution. The module executes continuous built-in diagnostics for fiber breakage, signal attenuation and link faults, forwarding all alarm information to the main processor. Safety and instrument engineers deploy this hardware to extend I/O placement far from the central control room. It enables flexible layout of ESD, fire and machinery protection points while preserving SIL 3 fault tolerance, avoiding costly long-distance hardwiring of field sensors and actuators.

Reviews

There are no reviews yet.

Be the first to review “TRICONEX 5411H | fiber optic remote I/O extender module”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products