GE 745‑W2‑P5‑G5‑HI | two‑winding configuration SR745 transformer management IED

$3,560.00

  • Product Model: 745‑W2‑P5‑G5‑HI
  • Brand: GE Multilin (GE Vernova)
  • Warranty: One Year
  • Input Voltage: 70‑265 V AC / 90‑300 V DC wide‑range auxiliary supply
  • Operating Temperature: ‑20 °C to +60 °C
  • Storage Temperature: ‑40 °C to +85 °C
Categories: Tags: SKU: 745‑W2‑P5‑G5‑HI
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

Technical Specifications

  • Product Model: 745‑W2‑P5‑G5‑HI
  • Brand: GE Multilin (GE Vernova)
  • Warranty: One Year
  • Input Voltage: 70‑265 V AC / 90‑300 V DC wide‑range auxiliary supply
  • Operating Temperature: ‑20 °C to +60 °C
  • Storage Temperature: ‑40 °C to +85 °C
  • Response Time: ≤30 ms transformer differential primary trip operate time
  • Protection Class: IP54 front panel, IP20 rear terminal section, draw‑out chassis design
  • Accuracy Class: Class 0.2S for protection‑grade and metering measurement
  • Output Frequency: 50 / 60 Hz adaptive power‑system frequency support
  • Rated Current Range: 1‑5 A CT secondary input; withstand 20× rated current for 1 second short‑time
  • Communication Interface: Front‑panel RS232, rear RS422/RS485, enhanced LCD local HMI
  • Supported Protocols: Modbus RTU, DNP3.0 Level 2
  • Overload Capacity: Internal surge and over‑voltage protection; CT shorting safety feature on draw‑out unit
  • Dimensions: 229 mm × 178 mm × 181 mm (9″H ×7″W ×7‑1/8″D), 19‑inch rack‑mount draw‑out construction
  • GE_SR745-W2-P1-G1-HI-A-L-R-E_10

Product Overview

The GE 745‑W2‑P5‑G5‑HI is a two‑winding configuration SR745 transformer management IED from GE Multilin, built for protection, monitoring and control of power transformers, autotransformers and shunt reactors in utility substations and heavy‑industrial power plants. This draw‑out‑format intelligent electronic device integrates percentage‑biased differential protection with inrush restraint, restricted earth‑fault protection, backup overcurrent, V/Hz over‑excitation supervision, tap‑changer control, RTD‑based thermal monitoring, loss‑of‑life insulation ageing calculation and disturbance recording in one hardware unit. It addresses common substation pain points including magnetizing‑inrush nuisance tripping, insufficient winding‑ground‑fault sensitivity, limited transformer asset‑ageing visibility, and high maintenance effort for legacy fixed‑case relays. Protection engineers, substation integrators and plant maintenance teams benefit from this unit; hot‑swap draw‑out chassis enables spare replacement without full cabinet power‑down, and the enhanced 40‑character front‑panel LCD supports local setpoint editing and real‑time value viewing. It fits green‑field substation deployment as well as drop‑in spare‑part replacement for existing SR745 installations.