Description
Former EPRO Germany, AMS 6500 machinery health monitor rack;2‑slot 3U Euro‑card, API 670 compliant relay output module;sub‑variants A6740‑10 / A6740‑12Emerson。
Technical Specifications
- Product Model: A6740 (A6740‑10, A6740‑12)
- Brand: Emerson (EPRO)
- Warranty: One Year
- System Platform: AMS 6500 Classic Machinery Health Monitor
- Power Supply: Back‑plane 24 V DC; typical power consumption 7 W
- Relay Channels: 16 × SPDT (Form‑C) galvanic isolated relay outputs (Common / NO / NC)
- Contact Rating: 5 A @ 250 V AC;5 A @ 30 V DC
- Logic Resource: Max 60 alarm‑source inputs; up to 30 configurable boolean logic expressions; support AND / OR / 2‑out‑of‑3 voting; configurable time‑delay 0‑30 s; per‑relay Normally‑Energized / Normally‑De‑energized fail‑safe setting via software
- Response Time: Relay action < 10 ms
- Operating Temperature: 0 °C ~ +65 °C; 5‑95 %RH non‑condensing; API 670 compliant
- Storage Temperature:‑40 °C ~ +85 °C
- Protection Class: IP20 module body; hot‑swap supported; occupies 2 slots (12 TE) in AMS 6500 rackemerson.kr
- Indicators: Power LED; 16‑channel individual relay status LED; front‑panel config service port
- Mechanical: 60 mm(W) × 128.4 mm(H) × 160 mm(D); weight approx. 450 g
- Field Wiring: External relay contacts connect to rear terminal assembly
Product Overview
A6740 is high‑density 16‑channel relay output module for Emerson AMS 6500 TSI system. It receives Clear / Alert / Danger alarm status from measurement cards (A6210, A6220, A6312 etc.), executes user‑defined boolean & voting logic, drives isolated hard‑relay contacts. It provides alarm lamps, PLC DI, ESD interlock and turbine trip signals. Supports flexible fail‑safe mode and time‑delay for protection logic.
Important notes:
Application Scenarios
- Steam‑turbine / gas‑turbine TSI cabinet: Vibration, thrust, speed alarm & turbine trip hard‑contact outputs.
- Centrifugal‑compressor machinery‑protection system: Interlock signals to ESD and safety‑PLC.
- Power‑plant turbo‑generator monitoring racks.
- Oil‑gas rotating‑equipment safety‑monitoring.
- Retrofit & spare‑part replacement for existing AMS 6500 installations.







Reviews
There are no reviews yet.