Description
Product Overview
The 915FK2101 is a ControlNet communication option board that plugs inside a Reliance FlexPak 3000 or WebPak 3000 DC drive and turns it into a slave node on a ControlNet network. The board carries its own microprocessor, which talks to one port of the board’s dual-port memory while the other port interfaces the drive’s Regulator board through a ribbon cable — so the drive’s start/stop commands, speed reference, parameter access and feedback data are exchanged as scheduled network traffic instead of hard-wired 4–20 mA and relay signals. Two BNC connectors accept dual-coaxial drops through passive taps, an RJ-45 Network Access Port gives temporary programming access, and a 9-pin D-shell allows direct RS-232 flash programming of the board. For plants running FlexPak or WebPak drives under central control, this removes discrete wiring per drive, enables drive-level diagnostics from the network, and keeps an obsolete drive in service when the original communication path fails.
Technical Specifications
- Brand: Reliance Electric
- Model: 915FK2101 (association reference printed on the kit label: 762.70.96)
- Product Type: ControlNet network communication option board (interface kit)
- Compatible Drives: FlexPak 3000 and WebPak 3000 DC drives
- Function: Makes the host drive a slave node on the ControlNet network — start/stop, reset, reference changes, parameter modification and drive monitoring over the network
- Network Interface: ControlNet, two BNC connectors (dual coaxial media, connects through a passive tap via drop cable)
- Network Access: RJ-45 Network Access Port for temporary access to the network and connected products
- Programming Port: 9-pin D-shell connector, RS-232 for flash-memory programming of the board
- Local Intelligence: Dedicated microprocessor with dual-port memory — one port to the microprocessor, one port to the drive’s Regulator board
- Drive Connection: Ribbon cable to the Regulator board; board mounts inside the drive chassis
- Input / Output (process data): Max. 8 words of scheduled data sent and received per drive; drive parameters mapped into integer files, feedback and reference data exchanged as scheduled traffic
- Power Supply: Powered from the drive’s internal power supply (no separate supply required)
- Compatibility Note: WebPak 3000 drives of version 1.1 or later require option board version 2.2 or later; FlexPak 3000 drives of version 4.2 or later accept all versions of this board
- Mounting: Internal plug-in PCB assembly inside the drive, Regulator board ribbon connection
- Dimensions / Weight: Compact PCB assembly; packaged interface kit approx. 1 kg shipping weight
- Operating Temp: Governed by the host drive’s enclosure ambient limits
- Reference Manual: D2-3425 (installation), with drive manual D2-3404 / D2-3405
- Warranty: One Year
- Condition: 100% New & Original
Key Notes
- Isolate and lock out incoming power before installing — the board sits on the Regulator board and is not intended for live insertion.
- On WebPak 3000, a pre-1.1 drive version will not accept this board; check the drive firmware label against the board revision before ordering.
- Two BNC ports are needed for a redundant media path; a single-port installation must be terminated correctly at both ends of the segment with 75 Ω terminators.








Reviews
There are no reviews yet.